MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1002/elps.200700409

Медицинская библиотека · Electrophoresis · 2008

Open-tubular capillary electrochromatography using a capillary coated with octadecylamine-capped gold nanoparticles.

Qu Qishu, Zhang Xinxin, Shen Ming, Liu Yin, Hu Xiaoya, Yang Gongjun, Wang Chengyin, Zhang Yukui, Yan Chao

СтатьяПоддержка исследования: вне правительства СШАПеревод в очереди

Аннотация

Octadecylamine-capped gold nanoparticles (ODA-Au-NPs) were prepared and characterized by using UV-Vis adsorption spectrum, transmission electron chromatography (TEM), SEM, and FT-IR. A simple but robust hydrophobic coating was easily developed by flushing a capillary with a solution of ODA-Au-NPs, because the positive charges were carried by the nanoparticles which strongly adsorb to the negatively charged inner surface of a fused-silica capillary via electrostatic and hydrophobic interactions. The chromatographic characteristics of the coated capillary was investigated by varying the experimental parameters such as buffer pH, buffer concentration, and percentage of organic modifier in the mobile phase. The results show that (i) resolution between thiourea and naphthalene is almost the same when comparing the electrochromatograms obtained using pH 7 buffer as mobile phase after and before the capillary column was operated using pH 11 and 3 mobile phase; (ii) no significant changes in retention time and deterioration in peak efficiency were found after 60 runs of test aromatic mixtures; and (iii) column efficiency up to 189 000 theoretical plates/meter for testosterone was obtained. All of the results indicated that the coating could act as a stable stationary phase for open tubular CEC as well as for bioanalysis.

Для цитирования: Qu Qishu, Zhang Xinxin, Shen Ming, Liu Yin, Hu Xiaoya, Yang Gongjun, Wang Chengyin, Zhang Yukui, Yan Chao. Open-tubular capillary electrochromatography using a capillary coated with octadecylamine-capped gold nanoparticles.. Electrophoresis. 2008. DOI: 10.1002/elps.200700409.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.