DOI 10.1161/01.cir.102.21.2643
Lack of direct role for calcium in ischemic diastolic dysfunction in isolated hearts.
Аннотация
BACKGROUND
Ischemia is characterized by an increase in intracellular calcium and occurrence of diastolic dysfunction. We investigated whether the myocyte calcium level is an important direct determinant of ischemic diastolic dysfunction.
METHODS AND
RESULTS
We exposed isolated, perfused isovolumic (balloon in left ventricle) rat and rabbit hearts to low-flow ischemia and increased extracellular calcium (from 1.5 to 16 mmol/L) for brief periods. Intracellular calcium was measured by aequorin. Low-flow ischemia resulted in a 270% increase (P:<0.05) in diastolic intracellular calcium, a 50% (P:<0.05) calcium transient amplitude decrease, and a 52% (P:<0.05) slowing of calcium transient decline. Diastolic pressure increased by 6+/-2 mm Hg (P:<0.05), and rate of systolic pressure decay decreased by 65% (P:<0.05). Experimentally increasing extracellular calcium doubled both intracellular diastolic calcium and calcium transient amplitude, concomitant with a developed pressure increase; however, there was no increase in ischemic diastolic pressure, slowing of the calcium transient decay, or further slowing of systolic pressure decay. Similarly, after 45 minutes of low-flow ischemia, after diastolic pressure had increased from 8.5+/-0.6 to 19.7+/-3.5 mm Hg (P:<0.001), intracoronary high-molar calcium chloride infusion increased systolic pressure from 36+/-4 to 63+/-11 mm Hg (P:<0.001), indicating an increase in intracellular calcium, but it decreased diastolic pressure from 19. 7+/-3.5 to 17.5+/-3.7 mm Hg (P:<0.01). Conversely, EGTA infusion decreased systolic pressure, indicating a decrease in intracellular calcium, but did not decrease diastolic pressure.
CONCLUSIONS
When calcium availability was experimentally altered during ischemia, there was no alteration in left ventricular diastolic pressure, suggesting that ischemic diastolic dysfunction is not directly mediated by a calcium activated tension.
Предметные рубрики MeSH
Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Ошибки и ограничения
История · было → стало
Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.
Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.