MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1093/chromsci/39.11.491

Медицинская библиотека · Journal of chromatographic science · 2001

Simultaneous determination of torasemide and its major metabolite M5 in human urine by high-performance liquid chromatography-electrochemical detection.

Barroso M B, Alonso R M, Jiménez R M

СтатьяПоддержка исследования: вне правительства СШАПеревод в очереди

Аннотация

A high-performance liquid chromatographic method with electrochemical detection is described for the simultaneous determination of the loop diuretic 1-isopropil-3-[4-(3-methylphenylamino)-3-pyridinesulphonyl]urea (torasemide) and its major metabolite M5 in human urine. The assay is simple, fast, and easy. It requires a sample cleanup consisting of a solid-phase extraction under acidic conditions followed by chromatographic separation with a C18 microBondapack column. The use of a water-acetonitrile mobile phase (80:20, v/v, pH 3) ensures total separation from urine-interfering substances, and both compounds can be quantitated amperometrically at a glassy carbon electrode set to +1300 mV versus Ag-AgCl. The method demonstrates linearity for both the parent drug and the metabolite over a wide concentration range (up to 7 microg/mL) and reproducibility with relative standard deviation lower than 2% in intraday and 5% in interday assays. The mean extraction recoveries are 78% for M5 and 60% for torasemide, and the limits of quantitation are 1 and 8 ng/mL, respectively. The method developed is applied to the analysis of healthy volunteers' urine samples collected at different time intervals after the oral ingestion of a single dose of 10 mg torasemide, and the results obtained are in agreement with the pharmacokinetic profile of torasemide.

Для цитирования: Barroso M B, Alonso R M, Jiménez R M. Simultaneous determination of torasemide and its major metabolite M5 in human urine by high-performance liquid chromatography-electrochemical detection.. Journal of chromatographic science. 2001. DOI: 10.1093/chromsci/39.11.491.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.