MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1007/s00595-017-1614-7

Медицинская библиотека · Surgery today · 2017

Predictors of the need for pacemaker implantation after the Cox maze IV procedure for atrial fibrillation.

Masaki Naoki, Kawamoto Shunsuke, Motoyoshi Naotaka, Adachi Osamu, Kumagai Kiichiro, Kawatsu Satoshi, Hayatsu Yukihiro, Katahira Shintaro, Hosoyama Katsuhiro, Akiyama Masatoshi, Saiki Yoshikatsu

СтатьяПеревод в очереди

Аннотация

PURPOSE: The Cox maze IV (CMIV) procedure is being used increasingly frequently for surgical ablation of atrial fibrillation (AF). This study aimed to identify the risk factors of the need for postoperative pacemaker implantation (PMI) after CMIV.

METHODS

Preoperative, intraoperative, and postoperative data were retrospectively collected from 67 consecutive patients who underwent CMIV at our institution; 7 (10.4%) required PMI (as a treatment of brady AF or sick sinus syndrome).

RESULTS

Patients who needed PMI tended to have lower preoperative heart rates than those who did not on a 12-lead electrocardiogram (ECG; 68.7 ± 11.6 vs. 79.1 ± 18.5 bpm, p = 0.07) and a 24-h ECG (94,772 ± 9800 vs. 109,854 ± 19,078 beats/day, p = 0.03). A multivariate analysis identified a low amplitude of the fibrillatory wave on preoperative ECG as a risk factor of PMI necessity after CMIV [odds ratio = 14.7; 95% confidence interval (CI) 1.9-324.7; p = 0.007] and internal use of angiotensin-converting enzyme inhibitors or angiotensin receptor blockers (ACEIs/ARBs) as a negative risk factor (odds ratio = 0.16; 95% CI 0.02-0.99; p = 0.049).

CONCLUSIONS

A low amplitude of the fibrillatory wave was identified as a risk factor of PMI necessity, whereas the internal use of ACEIs/ARBs diminished the need for PMI. These factors should be considered before CMIV is performed.

Для цитирования: Masaki Naoki, Kawamoto Shunsuke, Motoyoshi Naotaka, Adachi Osamu, Kumagai Kiichiro, Kawatsu Satoshi, Hayatsu Yukihiro, Katahira Shintaro, Hosoyama Katsuhiro, Akiyama Masatoshi, Saiki Yoshikatsu. Predictors of the need for pacemaker implantation after the Cox maze IV procedure for atrial fibrillation.. Surgery today. 2017. DOI: 10.1007/s00595-017-1614-7.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.