Journal of cardiology · 2006

Method analysis for optimal continuous imaging using intravascular optical coherence tomography.

СтатьяНазвание и аннотация: Перевод в очереди
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Asawa Koichiro, Kataoka Toru, Kobayashi Yoshiki, Hasegawa Takao, Nishioka Hiroki, Yamashita Hajime, Qiu Zhaohui, Ehara Shoichi, Hirose Makoto, Kamimori Kimio, Shimada Kenei, Yoshiyama Minoru, Yoshikawa Junichi

Аннотация

OBJECTIVES: Optical coherence tomography(OCT)is a high-resolution imaging method that can clearly visualize vessels through the displacement of blood with flushing agents. Continuous imaging methods have not been established. This study investigated optimal methods for continuous OCT imaging.

METHODS: Thirty-four arteries with stent implantation (24 peripheral and 10 coronary arteries)in 14 pigs were examined using OCT with a motorized pullback device. Two imaging methods (flush alone by liquid substance and flush with occlusion) were compared. Adequate image acquisition was defined as the entire circumferential intimal layer being detectable within continuous segments. To investigate factors that could influence image quality, stented regions were divided into 4-5 mm segments.

RESULTS: The flush with occlusion method provided better OCT images compared to flush alone (flush with occlusion: 60.9%, flush alone: 8.7%, p = 0.0002). Using the flush with occlusion method, the rate of adequate image acquisition was 64.4% and visualization of > 75% intimal circumference was 83.5%. Intravascular ultrasound could detect all stented regions. Segmental analyses found more adequate images were detected in smaller vessels (adequate segment: 3.8 +/- 0.4 mm, inadequate segment: 4.2 +/- 0.8 mm, p < 0.0001) or with centered image wire position (adequate segment: center 35%, inadequate segment: center 14%, p = 0.003). In addition, side branches did not affect image quality.

CONCLUSIONS: To acquire continuous OCT images, the flush with occlusion method was more effective compared to flush alone. Moreover, image quality is affected by vessel size and imaging wire position. These results suggest that optimized OCT imaging can provide continuous vessel detection.