MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1093/europace/eus069

Медицинская библиотека · Europace : European pacing, arrhythmias, and cardiac electrophysiology : journal of the working groups on cardiac pacing, arrhythmias, and cardiac cellular electrophysiology of the European Society of Cardiology · 2012

Heart failure in patients with sick sinus syndrome treated with single lead atrial or dual-chamber pacing: no association with pacing mode or right ventricular pacing site.

Riahi Sam, Nielsen Jens Cosedis, Hjortshøj Søren, Thomsen Poul Erik B, Højberg Søren, Møller Mogens, Dalsgaard Dorthe, Nielsen Tonny, Asklund Mogens, Friis Elsebeth V, Christensen Per D, Simonsen Erik H, Eriksen Ulrik H, Jensen Gunnar V H, Svendsen Jesper H, Toff William D, Healey Jeffrey S, Andersen Henning R, DANPACE Investigators

СтатьяПоддержка исследования: вне правительства СШАПеревод в очереди

Аннотация

AIMS: Previous studies indicate that ventricular pacing may precipitate heart failure (HF). We investigated occurrence of HF during long-term follow-up among patients with sick sinus syndrome (SSS) randomized to AAIR or DDDR pacing. Furthermore, we investigated effects of percentage of ventricular pacing (%VP) and pacing site in the ventricle.

METHODS AND

RESULTS

We analysed data from 1415 patients randomized to AAIR (n = 707) or DDDR pacing (n = 708). Ventricular pacing leads were recorded as located in either an apical or a non-apical position. The %VP and HF hospitalizations were recorded during follow-up. Patients were classified with new HF, if in New York Heart Association (NYHA) functional class IV or if presence of ≥2 of: oedema; dyspnoea; NYHA functional class III. Mean follow-up was 5.4 ± 2.4 years. Heart failure hospitalizations did not differ between groups. In the AAIR group, 170 of the 707 (26%) patients developed HF vs. 169 of the 708 (26%) patients in the DDDR group, hazard rate ratio (HR) 1.00, 95% confidence interval (CI) 0.79-1.22, P = 0.87. In DDDR patients, 146 of the 512 patients (29%) with ventricular leads in an apical position developed HF vs. 28 of the 161 patients (17%) with the leads in a non-apical position, HR 0.67, CI 0.45-1.00, P = 0.05. After adjustments this difference was non-significant. The incidence of HF was not associated with %VP (P = 0.57).

CONCLUSION

In patients with SSS, HF was not associated with pacing mode, %VP, or ventricular lead localization. This suggests that DDDR pacing is safe in patients with SSS without precipitating HF.

Для цитирования: Riahi Sam, Nielsen Jens Cosedis, Hjortshøj Søren, Thomsen Poul Erik B, Højberg Søren, Møller Mogens, Dalsgaard Dorthe, Nielsen Tonny, Asklund Mogens, Friis Elsebeth V, Christensen Per D, Simonsen Erik H, Eriksen Ulrik H, Jensen Gunnar V H, Svendsen Jesper H, Toff William D, Healey Jeffrey S, Andersen Henning R, DANPACE Investigators. Heart failure in patients with sick sinus syndrome treated with single lead atrial or dual-chamber pacing: no association with pacing mode or right ventricular pacing site.. Europace : European pacing, arrhythmias, and cardiac electrophysiology : journal of the working groups on cardiac pacing, arrhythmias, and cardiac cellular electrophysiology of the European Society of Cardiology. 2012. DOI: 10.1093/europace/eus069.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.