MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1002/mrm.1910400604

Медицинская библиотека · Magnetic resonance in medicine · 1998

In vivo topical EPR spectroscopy and imaging of nitroxide free radicals and polynitroxyl-albumin.

Kuppusamy P, Wang P, Shankar R A, Ma L, Trimble C E, Hsia C J, Zweier J L

СтатьяПоддержка исследования: вне правительства СШАПоддержка службы здравоохранения СШАПеревод в очереди

Аннотация

Piperidine nitroxides have considerable clinical potential, both as antioxidant therapeutic compounds and contrast agents in magnetic resonance imaging. However, their development has thus far been limited by their rapid bioreduction in vivo. Recently, it was reported that polynitroxyl albumin (PNA) can reverse the bioreduction of the reduced 4-hydroxy-2,2,6,6-tetramethylpiperidine-N-oxyl (Tempol) in the rat heart, enabling the performance of high resolution EPR imaging for prolonged time (Kuppusamy et al., Biochemistry 35, 7051-7057 (1996)). In this report, the efficacy of PNA in maintaining Tempol concentrations in vivo in mice was demonstrated, using L-band (1.25 GHz) EPR spectroscopy and imaging. The EPR signal of intravenous Tempol had a half-life of 1.0+/-0.2 min and became undetectable within 6 min. Subcutaneous Tempol, however, decayed at a slower rate (half-life, 5.0+/-0.5 min) suggesting that Tempol had been bioreduced to the corresponding hydroxylamine form, Tempol-H. Subcutaneously injected PNA restored 20% of the Tempol signal in the vicinity of the PNA deposit. In vivo topical EPR imaging demonstrated that the Tempol signal was restored at the site of PNA injection, but not at locations remote from the PNA injection site. The ability of PNA to maintain Tempol in its paramagnetic state in vivo should enable a wide range of therapeutic and diagnostic applications of piperidinyl nitroxides.

Для цитирования: Kuppusamy P, Wang P, Shankar R A, Ma L, Trimble C E, Hsia C J, Zweier J L. In vivo topical EPR spectroscopy and imaging of nitroxide free radicals and polynitroxyl-albumin.. Magnetic resonance in medicine. 1998. DOI: 10.1002/mrm.1910400604.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.