MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1006/abio.1998.2651

Медицинская библиотека · Analytical biochemistry · 1998

Nitrosothiol quantification in human plasma.

Goldman R K, Vlessis A A, Trunkey D D

СтатьяПеревод в очереди

Аннотация

A high-pressure liquid chromatography (HPLC) assay for measuring picomole quantities of nitrosothiol in biological samples was developed. The assay utilizes the catalytic reduction of nitrosothiol by mercuric cation (Hg2+). Released nitrogen oxide reacts with sulfanilamide (SA) and N-(1-napthyl)ethylenediamine (NNED) to form a stable azo dye. The azo dye is then separated from N-(1-napthyl)ethylenediamine and quantified by reversed-phase HPLC. In addition to nitrosothiol, nitrite and atmospheric nitrogen oxides are sources of nitrogen oxide that react with the reagents, SA and NNED, to form the azo dye. Therefore, a reference sample, which includes the nitrosothiol sample and all reagents except Hg2+, is utilized for the subtraction of nitrite and atmospheric nitrogen oxides which "contaminate" the nitrosothiol sample and reagents. This method is a sensitive (approximately 3 pmol; approximately 10(-1) microM) and accurate means to measure nitrosothiol concentration in biologic samples.

Для цитирования: Goldman R K, Vlessis A A, Trunkey D D. Nitrosothiol quantification in human plasma.. Analytical biochemistry. 1998. DOI: 10.1006/abio.1998.2651.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.