MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1016/j.rpor.2017.12.004

Медицинская библиотека · Reports of practical oncology and radiotherapy : journal of Greatpoland Cancer Center in Poznan and Polish Society of Radiation Oncology · 2018

Energy spectrum and dose enhancement due to the depth of the Lipiodol position using flattened and unflattened beams.

Kawahara Daisuke, Ozawa Shuichi, Saito Akito, Kimura Tomoki, Suzuki Tatsuhiko, Tsuneda Masato, Tanaka Sodai, Hioki Kazunari, Nakashima Takeo, Ohno Yoshimi, Murakami Yuji, Nagata Yasushi

СтатьяПеревод в очереди

Аннотация

AIM: Lipiodol was used for stereotactic body radiotherapy combining trans arterial chemoembolization. Lipiodol used for tumour seeking in trans arterial chemoembolization remains in stereotactic body radiation therapy. In our previous study, we reported the dose enhancement effect in Lipiodol with 10× flattening-filter-free (FFF). The objective of our study was to evaluate the dose enhancement and energy spectrum of photons and electrons due to the Lipiodol depth with flattened (FF) and FFF beams.

METHODS

FF and FFF for 6 MV beams from TrueBeam were used in this study. The Lipiodol (3 × 3 × 3 cm3) was located at depths of 1, 3, 5, 10, 20, and 30 cm in water. The dose enhancement factor (DEF) and the energy fluence were obtained by Monte Carlo calculations of the particle and heavy ion transport code system (PHITS).

RESULTS

The DEFs at the centre of Lipiodol with the FF beam were 6.8, 7.3, 7.6, 7.2, 6.1, and 5.7% and those with the FFF beam were 20.6, 22.0, 21.9, 20.0, 12.3, and 12.1% at depths of 1, 3, 5, 10, 20, and 30 cm, respectively, where Lipiodol was located in water. Moreover, spectrum results showed that more low-energy photons and electrons were present at shallow depth where Lipiodol was located in water. The variation in the low-energy spectrum due to the depth of the Lipiodol position was more explicit with the FFF beam than that with the FF beam.

CONCLUSIONS

The current study revealed variations in the DEF and energy spectrum due to the depth of the Lipiodol position with the FF and FFF beams. Although the FF beam could reduce the effect of energy dependence due to the depth of the Lipiodol position, the dose enhancement was overall small. To cause a large dose enhancement, the FFF beam with the distance of the patient surface to Lipiodol within 10 cm should be used.

Для цитирования: Kawahara Daisuke, Ozawa Shuichi, Saito Akito, Kimura Tomoki, Suzuki Tatsuhiko, Tsuneda Masato, Tanaka Sodai, Hioki Kazunari, Nakashima Takeo, Ohno Yoshimi, Murakami Yuji, Nagata Yasushi. Energy spectrum and dose enhancement due to the depth of the Lipiodol position using flattened and unflattened beams.. Reports of practical oncology and radiotherapy : journal of Greatpoland Cancer Center in Poznan and Polish Society of Radiation Oncology. 2018. DOI: 10.1016/j.rpor.2017.12.004.
Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.