MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1152/jappl.1996.80.3.862

Медицинская библиотека · Journal of applied physiology (Bethesda, Md. : 1985) · 1996

N-tert-butyl-alpha-phenylnitrone: a free radical trap with unanticipated effects on diaphragm function.

Andersen K A, Diaz P T, Wright V P, Clanton T L

СтатьяПоддержка исследования: вне правительства СШАПоддержка службы здравоохранения СШАПеревод в очереди

Аннотация

The spin trap N-tert-butyl-alpha-phenylnitrone (PBN) has a high avidity for free radical species and hence functions as an antioxidant in many biological systems. As such, we hypothesized that PBN would have powerful antioxidant effects on muscle function. We examined the effects of PBN on directly stimulated in vitro (37 degrees C) rat diaphragm. First, a dose-response curve for the effects of PBN on force frequency (n = 8) was established by comparing PBN-treated muscle strips (0.01-10 mM) with time- and stimulus-matched control strips. Second, the effect of 1.0 mM PBN on muscle endurance (n = 8) was established. Our findings were as follows. 1) Compared with baseline, peak twitch and low-frequency muscle tensions increased in a dose-dependent fashion, with peak effects at 1.0 mM PBN. 2) Muscle function at all stimulation frequencies was depressed at doses above 1.0 mM PBN. 3) Complete inhibition at 10 mM PBN was reversed with caffeine administration or washout. 4) During early fatigue, 1.0 mM PBN facilitated force. However, endurance time decreased in the PBN-treated group. We conclude that PBN has direct reversible dose-dependent effects on diaphragm function. However, facilitation of low-frequency forces and the lack of fatigue-attenuating properties suggest that PBN has atypical antioxidant effects on muscle function.

Для цитирования: Andersen K A, Diaz P T, Wright V P, Clanton T L. N-tert-butyl-alpha-phenylnitrone: a free radical trap with unanticipated effects on diaphragm function.. Journal of applied physiology (Bethesda, Md. : 1985). 1996. DOI: 10.1152/jappl.1996.80.3.862.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.