MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1007/s10439-019-02346-6

Медицинская библиотека · Annals of biomedical engineering · 2019

Development of a Bioactive Polymeric Drug Eluting Coronary Stent Coating Using Electrospraying.

McKittrick C M, Cardona M J, Black R A, McCormick C

СтатьяПеревод в очереди

Аннотация

Drug-eluting stents are now routinely used in the treatment of acute coronary syndromes caused by coronary artery disease. Whilst the sustained release of anti-proliferative drugs from these devices has greatly reduced the need for repeat revascularisation procedures, this approach is not suitable for all patients and appears to delay regrowth of the endothelium, necessitating the use of prolonged dual anti-platelet therapy. Although the development of more advanced stent platforms and drug coatings has produced modest improvements in performance, these devices have not fully addressed the limitations experienced with their first-generation counterparts. In the present study, we developed a novel stent coating that provides controlled sirolimus release from a bioactive polymer (accelerate™ AT) that has previously been shown to support endothelial cell growth in vitro. A bespoke electrospray deposition process provided control over the coating thickness, surface roughness, drug load, and release kinetics. The resultant optimised coating combines rapid release of an anti-proliferative agent from a bioactive polymer coating that promotes re-endothelialisation, thereby offering potential protection against in-stent restenosis and thrombosis. This novel, dual-action coating therefore has significant therapeutic potential, with the enhanced control of drug load and release kinetics offered by electrospray deposition also opening up opportunities for more personalised treatment approaches. Further development and evaluation of these technologies in vitro and in vivo is therefore warranted.

Для цитирования: McKittrick C M, Cardona M J, Black R A, McCormick C. Development of a Bioactive Polymeric Drug Eluting Coronary Stent Coating Using Electrospraying.. Annals of biomedical engineering. 2019. DOI: 10.1007/s10439-019-02346-6.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.