DOI 10.1016/j.jtcvs.2018.08.117
Nitric oxide provides myocardial protection when added to the cardiopulmonary bypass circuit during cardiac surgery: Randomized trial.
Аннотация
OBJECTIVES
The aim of this pilot study was to elucidate the effects of exogenous nitric oxide (NO) supply to the extracorporeal circulation circuit for cardioprotection against ischemia-reperfusion injury during coronary artery bypass grafting (CABG) with cardiopulmonary bypass (CPB).
METHODS
A total of 60 patients with coronary artery disease scheduled for CABG with CPB were enrolled in a prospective randomized study. Patients were allocated randomly to receive treatment according to standard or modified CPB protocol where 40-ppm NO was added to the CPB circuit during cardiac surgery. The primary endpoint was the measurement of cardiac troponin I (cTnI). The secondary end points consisted in the measurements of creatine kinase-muscle/brain fraction (CK-MB) and vasoactive inotropic score (VIS).
RESULTS
NO delivered into the CPB circuit had a cardioprotective effect. The level of cTnI was significantly lower in NO-treated group compared with the control group 6 hours after surgery: 1.79 ± 0.39 ng/mL versus 2.41 ± 0.55 ng/mL, respectively (P = .001). The CK-MB value was significantly lower in NO-treated group compared with the control group 24 hours after surgery: 47.69 ± 8.08 U/L versus 62.25 ± 9.78 U/L, respectively (P = .001); and the VIS was significantly lower in the NO-treated group 6 hours after the intervention.
CONCLUSIONS
NO supply to the CPB circuit during CABG exerted a cardioprotective effect and was associated with lower levels of VIS and cardiospecific blood markers cTnI and CK-MB.