Noninvasive peripheral vascular function and atrial fibrillation in the general population.
Аннотация
BACKGROUND
Arterial stiffness is a strong predictor of atrial fibrillation in the community. Whether noninvasively measured conduit artery function and peripheral vascular reactivity are related to atrial fibrillation remains unknown.
METHODS AND
RESULTS
In 15 010 individuals of the population-based Gutenberg Health Study, mean age 55 ± 11 years, 50.5% men, we determined noninvasive vascular function by flow-mediated dilation (FMD) and peripheral arterial tonometry (PAT) in relation to manifest atrial fibrillation (N = 466). Patients with atrial fibrillation exhibited a higher mean brachial artery diameter [4.81 mm (4.17, 5.33) in atrial fibrillation vs. 4.31 mm (3.67, 4.93)] and baseline pulse amplitude in arbitrary units [6.35 (5.76, 6.78) in atrial fibrillation vs. 6.09 (5.36, 6.71)] as well as a reduced FMD in arbitrary units [1.29 (1.26, 1.33) in atrial fibrillation vs. (1.31 (1.26, 1.37)] and PAT ratio [0.42 (0.19, 0.77) in atrial fibrillation vs. 0.67 (0.33, 0.94)] compared with individuals without atrial fibrillation (all PWilcoxon rank-sum test). In age-adjusted and sex-adjusted logistic regression analyses, only baseline brachial artery diameter [odds ratio (OR) per standard deviation 1.19; 95% confidence interval (CI), 1.04-1.37; P = 0.012] and PAT ratio (OR 0.83; 0.74-0.94; P = 0.0029) were associated with atrial fibrillation. In risk factor and heart rate-adjusted models, there was no statistically significant correlation of atrial fibrillation and brachial artery diameter, FMD and PAT ratio while baseline pulse amplitude was reduced in individuals with atrial fibrillation (OR 0.81; 95% CI 0.71-0.93; P = 0.0034).
CONCLUSION
In our large contemporary cohort, peripheral vascular function was compromised in individuals with atrial fibrillation. However, observed associations were mediated by age and classical risk factors. Noninvasive vascular function measures did not improve discriminatory ability for atrial fibrillation.
Предметные рубрики MeSH
Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Ошибки и ограничения
История · было → стало
Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.
Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.