MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1111/jce.13262

Медицинская библиотека · Journal of cardiovascular electrophysiology · 2017

Autonomic nervous system modulation and clinical outcome after pulmonary vein isolation using the second-generation cryoballoon.

Miyazaki Shinsuke, Nakamura Hiroaki, Taniguchi Hiroshi, Hachiya Hitoshi, Kajiyama Takatsugu, Watanabe Tomonori, Igarashi Miyako, Ichijo Sadamitsu, Hirao Kenzo, Iesaka Yoshito

СтатьяПеревод в очереди

Аннотация

BACKGROUND

The intrinsic cardiac autonomic nervous system (ANS) plays a significant role in atrial fibrillation (AF) mechanisms. This study evaluated the incidence and impact of intraprocedural vagal reactions and ANS modulation by pulmonary vein isolation (PVI) using second-generation cryoballoons on outcomes.

METHODS

One hundred three paroxysmal AF patients underwent PVI with one 28-mm second-generation balloon. The median follow-up was 15.0 (12.0-18.0) months. ANS modulation was defined as a >20% cycle length decrease on 3-minute resting electrocardiograms at 1, 3, 6, and 12 months postindex procedure relative to baseline if sinus rhythm was maintained.

RESULTS

Marked sinus arrests/bradycardia and atrioventricular block (intraprocedural vagal reaction) occurred in 14 and 2 patients, and all sinus arrest/bradycardia occurred in 44 patients with left superior pulmonary veins (PVs) targeted before right PVs. ANS modulation was identified in 66 of 95 (69.5%) patients, and it persisted 12-month postprocedure in 36 (37.9%) patients. Additional β-blocker administration was required in 9 patients for sinus tachycardia. ANS modulation was similarly observed in patients with and without intraprocedural vagal reactions (P = 0.443). Forty-eight (46.6%) patients experienced early recurrences, and the single procedure success at 12 months was 72.7%. Neither intraprocedural vagal reactions nor ANS modulation predicted AF freedom within or after the blanking period. Thirty-three patients underwent second procedures, and reconnections were detected in 39 of 130 (30.0%) PVs among 23 (69.7%) patients. The incidence of reconnections was similar in patients with and without ANS modulation.

CONCLUSIONS

Increased heart rate persisted in 37.9% of patients even at 12-month post-second-generation cryoballoon PVI. Neither intraprocedural vagal reactions nor increased heart rate predicted a single procedure clinical outcome.

Для цитирования: Miyazaki Shinsuke, Nakamura Hiroaki, Taniguchi Hiroshi, Hachiya Hitoshi, Kajiyama Takatsugu, Watanabe Tomonori, Igarashi Miyako, Ichijo Sadamitsu, Hirao Kenzo, Iesaka Yoshito. Autonomic nervous system modulation and clinical outcome after pulmonary vein isolation using the second-generation cryoballoon.. Journal of cardiovascular electrophysiology. 2017. DOI: 10.1111/jce.13262.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.