DOI 10.1007/s12928-017-0502-9

Медицинская библиотека · Cardiovascular intervention and therapeutics · 2017

Efficacy and safety of transcatheter aortic valve implantation with Edwards SAPIEN 3 and XT in smaller Asian anatomy.

Nakashima Makoto, Watanabe Yusuke, Hioki Hirofumi, Nara Yugo, Nagura Fukuko, Hosogoe Naoyoshi, Kawashima Hideyuki, Kataoka Akihisa, Otsuki Shuji, Konno Kumiko, Kyono Hiroyuki, Yokoyama Naoyuki, Kozuma Ken

Сравнительное исследованиеСтатьяНаблюдательное исследованиеПеревод в очереди

Аннотация

We aimed to compare the efficacy and safety of transcatheter aortic valve implantation (TAVI) using Edwards SAPIEN 3 (S3) valve and SAPIEN XT) in smaller anatomy. The new generation S3 TAVI device has been used worldwide; however, its efficacy and safety in smaller Asian anatomy remain unknown. Between February 2014 and March 2017, 166 consecutive patients (S3, 54; XT, 112) were treated with balloon-expandable TAVI in a single center and their outcomes were analyzed. Median patient age was 85 (range: 81-88) years and mean body surface area was 1.41 ± 0.15 m2. A 23-mm size valve was used in S3 and XT groups (70 vs. 62%, p = 0.224). The transfemoral approach was more frequently used in the S3 than in the XT group (96 vs. 72%, p < 0.001). Although, the minimal luminal diameter of the femoral artery was smaller in the S3 group (5.9 vs. 6.4 mm, p = 0.001), the rates of major (2 vs. 11%, p = 0.226) and minor (11 vs. 5%, p = 0.107) vascular complications did not increase. The frequency of paravalvular leaks (PVL) ≥ 2 was significantly reduced in the S3 group (11 vs. 61%, p < 0.001); however, pre- (24 vs. 91%, p < 0.001) and post- (4 vs. 19%, p < 0.001) dilatations were less frequently performed. Pacemaker implantation incidence did not increase (4 vs. 5%, p = 1.0) and peak velocity of the transcatheter heart valve was significantly higher in the S3 group (2.3 vs. 2.2 m/s, p = 0.046). Device success was high (89 vs. 93%, p = 0.387) while the 30-day all-cause mortality was low (2 vs. 1%, p = 0.583) in both groups. TAVI with the S3 device was safe and effective, with low incidence of vascular complications and reduced PVL, in smaller body-sized Asians.

Для цитирования: Nakashima Makoto, Watanabe Yusuke, Hioki Hirofumi, Nara Yugo, Nagura Fukuko, Hosogoe Naoyoshi, Kawashima Hideyuki, Kataoka Akihisa, Otsuki Shuji, Konno Kumiko, Kyono Hiroyuki, Yokoyama Naoyuki, Kozuma Ken. Efficacy and safety of transcatheter aortic valve implantation with Edwards SAPIEN 3 and XT in smaller Asian anatomy.. Cardiovascular intervention and therapeutics. 2017. DOI: 10.1007/s12928-017-0502-9.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.