MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1016/j.rmed.2011.09.005

Медицинская библиотека · Respiratory medicine · 2011

Development of the i-BODE: validation of the incremental shuttle walking test within the BODE index.

Williams Johanna E A, Green Ruth H, Warrington Vicki, Steiner Michael C, Morgan Mike D L, Singh Sally J

СтатьяПоддержка исследования: вне правительства СШАВалидационное исследованиеПеревод в очереди

Аннотация

BACKGROUND

The BODE index has been shown to predict mortality in COPD. The index includes the 6 min walking test as the measure of exercise capacity. The incremental shuttle walking test (ISWT) is an alternative measure of exercise capacity which can be used to prescribe exercise and has been found to correlate well with peak VO2. The objective of the study was to evaluate the incorporation of the ISWT within the BODE index (named the i-BODE) to predict mortality in COPD.

METHODS

Data was analysed from 633 patients with COPD attending pulmonary rehabilitation over an 11 year period, and mortality determined a minimum of one year on from initial assessment. An i-BODE score was calculated using ISWT(m) then Cox regression analysis evaluated the capacity of the index to predict risk of death.

RESULTS

BMI, ISWT (m), MRC dyspnoea score, pack years and age were all significantly associated with mortality. Cox regression revealed the i-BODE index was an independent and significant predictor of mortality (hazard ratio 1.27 (CI 1.17-1.35), p < 0.001) and Kaplan Meier survival analysis showed each quartile increase in severity in i-BODE score was significantly associated with increased mortality (p < 0.001 by log rank test).

CONCLUSION

We have found the i-BODE index to be an independent predictor of mortality in COPD, even when other strong predictors such as age and pack years are adjusted for. We conclude that the ISWT can be successfully substituted for the 6MWT as an alternative measure of exercise capacity within the BODE index.

Для цитирования: Williams Johanna E A, Green Ruth H, Warrington Vicki, Steiner Michael C, Morgan Mike D L, Singh Sally J. Development of the i-BODE: validation of the incremental shuttle walking test within the BODE index.. Respiratory medicine. 2011. DOI: 10.1016/j.rmed.2011.09.005.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.