m+Medelevator.RU
← Поиск публикаций
Clinical and applied thrombosis/hemostasis : official journal of the International Academy of Clinical and Applied Thrombosis/Hemostasis · 2021

Caution in Using the Activated Partial Thromboplastin Time to Monitor Argatroban in COVID-19 and Vaccine-Induced Immune Thrombocytopenia and Thrombosis (VITT).

СтатьяНазвание и аннотация: Перевод в очереди
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Guy Susan, Kitchen Steve, Makris Michael, M Maclean Rhona, Saccullo Giorgia, Vanveen Joost J

Аннотация

INTRODUCTION: Argatroban is licensed for patients with heparin-induced thrombocytopenia and is conventionally monitored by activated partial thromboplastin time (APTT) ratio. The target range is 1.5 to 3.0 times the patients' baseline APTT and not exceeding 100 s, however this baseline is not always known. APTT is known to plateau at higher levels of argatroban, and is influenced by coagulopathies, lupus anticoagulant and raised FVIII levels. It has been used as a treatment for COVID-19 and Vaccine-induced Immune Thrombocytopenia and Thrombosis (VITT). Some recent publications have favored the use of anti-IIa methods to determine the plasma drug concentration of argatroban.

METHODS: Plasma of 60 samples from 3 COVID-19 patients and 54 samples from 5 VITT patients were tested by APTT ratio and anti-IIa method (dilute thrombin time dTT). Actin FS APTT ratios were derived from the baseline APTT of the patient and the mean normal APTT.

RESULTS: Mean APTT ratio derived from baseline was 1.71 (COVID-19), 1.33 (VITT) compared to APTT ratio by mean normal 1.65 (COVID-19), 1.48 (VITT). dTT mean concentration was 0.64 µg/ml (COVID-19) 0.53 µg/ml (VITT) with poor correlations to COVID-19 baseline APTT ratio r2 = 0.1526 p <0.0001, mean normal r2 = 0.2188 p < 0.0001; VITT baseline APTT ratio r2 = 0.04 p < 0.001, VITT mean normal r2 = 0.0064 p < 0.001.

CONCLUSIONS: We believe that dTT is a superior method to monitor the concentration of argatroban, we have demonstrated significant differences between APTT ratios and dTT levels, which could have clinical impact. This is especially so in COVID-19 and VITT.

Предметные рубрики MeSH

ИП Урсолов Владлен Сергеевич

ИНН 500118482352 · ОГРНИП 314500117700049

Реквизиты и контакты