MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1093/bja/aer265

Медицинская библиотека · British journal of anaesthesia · 2011

Oxygen delivery through high-flow nasal cannulae increase end-expiratory lung volume and reduce respiratory rate in post-cardiac surgical patients.

Corley A, Caruana L R, Barnett A G, Tronstad O, Fraser J F

СтатьяПоддержка исследования: вне правительства СШАПеревод в очереди

Аннотация

BACKGROUND

High-flow nasal cannulae (HFNCs) create positive oropharyngeal airway pressure, but it is unclear how their use affects lung volume. Electrical impedance tomography allows the assessment of changes in lung volume by measuring changes in lung impedance. Primary objectives were to investigate the effects of HFNC on airway pressure (P(aw)) and end-expiratory lung volume (EELV) and to identify any correlation between the two. Secondary objectives were to investigate the effects of HFNC on respiratory rate, dyspnoea, tidal volume, and oxygenation; and the interaction between BMI and EELV.

METHODS

Twenty patients prescribed HFNC post-cardiac surgery were investigated. Impedance measures, P(aw), ratio, respiratory rate, and modified Borg scores were recorded first on low-flow oxygen and then on HFNC.

RESULTS

A strong and significant correlation existed between P(aw) and end-expiratory lung impedance (EELI) (r=0.7, P<0.001). Compared with low-flow oxygen, HFNC significantly increased EELI by 25.6% [95% confidence interval (CI) 24.3, 26.9] and P(aw) by 3.0 cm H(2)O (95% CI 2.4, 3.7). Respiratory rate reduced by 3.4 bpm (95% CI 1.7, 5.2) with HFNC use, tidal impedance variation increased by 10.5% (95% CI 6.1, 18.3), and ratio improved by 30.6 mm Hg (95% CI 17.9, 43.3). A trend towards HFNC improving subjective dyspnoea scoring (P=0.023) was found. Increases in EELI were significantly influenced by BMI, with larger increases associated with higher BMIs (P<0.001).

CONCLUSIONS

This study suggests that HFNCs reduce respiratory rate and improve oxygenation by increasing both EELV and tidal volume and are most beneficial in patients with higher BMIs.

Для цитирования: Corley A, Caruana L R, Barnett A G, Tronstad O, Fraser J F. Oxygen delivery through high-flow nasal cannulae increase end-expiratory lung volume and reduce respiratory rate in post-cardiac surgical patients.. British journal of anaesthesia. 2011. DOI: 10.1093/bja/aer265.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.