MedElevator Войти в исследования
← Поиск публикаций

DOI 10.3390/jcm10163587

Медицинская библиотека · Journal of clinical medicine · 2021

Failure of High-Flow Nasal Cannula Therapy in Pneumonia and Non-Pneumonia Sepsis Patients: A Prospective Cohort Study.

Kim Eunhye, Jeon Kyeongman, Oh Dong Kyu, Cho Young-Jae, Hong Sang-Bum, Lee Yeon Joo, Lee Sang-Min, Suh Gee Young, Park Mi-Hyeon, Lim Chae-Man, Park Sunghoon, On Behalf Of The Korean Sepsis Alliance Ksa Investigators

СтатьяПеревод в очереди

Аннотация

Despite the increasing use of high-flow nasal cannulas (HFNCs) to treat critically ill patients, data on their effectiveness for sepsis patients remains very limited. We studied a prospective cohort of sepsis patients from the Korean Sepsis Registry (18 intensive care units (ICUs)). Patients started on HFNC therapy for hypoxemia within the first three ICU days were enrolled. HFNC failure was defined as intubation or ICU death, and the primary outcome was early HFNC failure occurring within 72 h of HFNC initiation. Of 901 patients with sepsis admitted to the ICU, 206 who received HFNC therapy were finally included (117 with pneumonia vs. 89 with non-pneumonia sepsis; median age, 71.0 (63.0-78.0) years; PaO2/FiO2 ratio, 160.2 (107.9-228.2) mm Hg; septic shock, n = 81 (39.3%)). During HFNC therapy, 72 (35.0%) patients were intubated and 51 (24.8%) died. HFNC failure developed in 95 (46.1%) patients, and among them, early failure rate was 85.3% (81/95). On multivariate analysis, an immunocompromised state (odds ratio (OR) = 2.730), use of a combination of antibiotics (OR = 0.219), and the PaO2/FiO2 ratio (OR = 0.308) were significantly associated with early HFNC failure in pneumonia sepsis patients. However, in non-pneumonia sepsis patients, lactate levels (OR = 1.532) were significantly associated with early HFNC failure. In conclusion, a high proportion of sepsis patients experience HFNC failure, usually within 72 h after therapy initiation, which emphasizes the importance of close monitoring. Furthermore, unlike in pneumonia sepsis, organ failure (i.e., lactate) might serve as a prognostic marker in non-pneumonia sepsis (i.e., type IV respiratory failure).

Для цитирования: Kim Eunhye, Jeon Kyeongman, Oh Dong Kyu, Cho Young-Jae, Hong Sang-Bum, Lee Yeon Joo, Lee Sang-Min, Suh Gee Young, Park Mi-Hyeon, Lim Chae-Man, Park Sunghoon, On Behalf Of The Korean Sepsis Alliance Ksa Investigators. Failure of High-Flow Nasal Cannula Therapy in Pneumonia and Non-Pneumonia Sepsis Patients: A Prospective Cohort Study.. Journal of clinical medicine. 2021. DOI: 10.3390/jcm10163587.
Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.