m+Medelevator.RU
← Поиск публикаций
Rapid communications in mass spectrometry : RCM · 2019

High-throughput method to analyze tegafur and 5-fluorouracil in human tears and plasma using hydrophilic interaction liquid chromatography/tandem mass spectrometry.

Оценочное исследованиеСтатьяНазвание и аннотация: Перевод в очереди
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Shiokawa Ritsuko, Lee Xiao-Pen, Yamada Miho, Fujishiro Masaya, Sakamaki Hiroshi, Hasegawa Chika, Ishida Hiroo, Ikeda Kenichiro, Fujita Ken-Ichi, Iwabuchi Shigehiro, Onda Hidetoshi, Kumazawa Takeshi, Sasaki Yasutsuna, Sato Keizo, Matsuyama Takaaki

Аннотация

RATIONALE: We developed a new high-throughput method to analyze tegafur (FT) and 5-fluorouracil (5-FU) in tear and plasma samples using hydrophilic interaction liquid chromatography (HILIC)/tandem mass spectrometry (MS/MS).

METHODS: The tear samples (10 μL) spiked with FT, 5-FU, and 5-chlorouracil (internal standard) were diluted using 40 μL of 2 M ammonium acetate and 250 μL of acetonitrile with 2% formic acid; 20 μL of plasma spiked with the two drugs and internal standard was diluted with 80 μL of 2 M ammonium acetate and 500 μL of acetonitrile with 2% formic acid. After centrifugation, the clear supernatant extract (15 μL) was directly injected into the HILIC/MS/MS instrument, and each drug was separated on a Unison UK-Amino column (50 mm × 3 mm i.d., 3 μm particle size) with a linear gradient elution system composed of 10 mM ammonium acetate (pH 6.8) and acetonitrile at a flow rate of 0.7 mL/min. We performed quantification by multiple reaction monitoring (MRM) with negative-ion atmospheric-pressure chemical ionization.

RESULTS: Distinct peaks were observed for the drugs on each MRM channel within 2 min. The regression equations showed good linearity within the range 0.04-4.0 μg/mL for the tear and plasma samples with detection limits at 0.02-0.04 μg/mL. Recoveries for target analytes (FT and 5-FU) for the tear and plasma samples were in the 94-128% and 94-104% ranges, respectively. The intra- and inter-day coefficients of variation for the two drugs were lower than 10.8%. The accuracies of quantitation were 97-115% for both samples.

CONCLUSIONS: We established a high-throughput, reproducible, and practical procedure for analyzing FT and 5-FU in human tear and plasma samples using HILIC/MS/MS analysis with an aminopropyl-bonded mixed-mode separation column. This method can be applied to the high-throughput routines used in clinical analyses.

Предметные рубрики MeSH

ИП Урсолов Владлен Сергеевич

ИНН 500118482352 · ОГРНИП 314500117700049

Реквизиты и контакты