MedElevator Войти в исследования
← Поиск публикаций

DOI 10.3978/j.issn.2072-1439.2014.02.20

Медицинская библиотека · Journal of thoracic disease · 2014

Comparison of MALDI-TOF MS, gene sequencing and the Vitek 2 for identification of seventy-three clinical isolates of enteropathogens.

Deng Jiankai, Fu Liang, Wang Ruilian, Yu Nan, Ding Xixia, Jiang Lingxiao, Fang Yanping, Jiang Changhong, Lin Lijuan, Wang Ying, Che Xiaoyan

СтатьяПеревод в очереди

Аннотация

OBJECTIVE

This study was performed to evaluate the analytical and practical performance of the matrix-assisted laser desorption ionization-time of flight mass spectrometry (MALDI-TOF MS) compared to the sequencing method and the Vitek 2 system for identification of enteropathogens in the clinical microbiology laboratory.

METHODS

Ten type strains and 73 clinical isolates of enteropathogens representing eight genera were analyzed by MALDI-TOF MS. All isolates were also characterized by gene sequencing allowing interpretation of the results from MALDI-TOF MS. In addition, MALDI-TOF MS was compared with the Vitek 2 system for the identification of ten isolates of Aeromonas and six of Salmonella.

RESULTS

As previously known, identification between Shigella and Escherichia coli is not possible to distinguish. MALDI-TOF MS produced the correct identifications for all other type strains and clinical isolates to the genus level. Fifteen Campylobacter jejuni, six Campylobacter coli, three Plesiomonas shigelloides, three Yersinia enterocolitica, two Clostridium difficile, one Vibrio parahaemolyticus, one Vibrio fluvialis, and one Vibrio cholera were all correctly identified to the species level. Genus and species identifications of ten Aeromonas and six Salmonella isolates by MALDI-TOF MS were consistent with those by the Vitek 2, but with much less cost and about ten times faster.

CONCLUSIONS

This study demonstrates that MALDI-TOF MS is a powerful tool for fast, accurate and low-cost identification of enteropathogens in the clinical microbiology laboratory.

Для цитирования: Deng Jiankai, Fu Liang, Wang Ruilian, Yu Nan, Ding Xixia, Jiang Lingxiao, Fang Yanping, Jiang Changhong, Lin Lijuan, Wang Ying, Che Xiaoyan. Comparison of MALDI-TOF MS, gene sequencing and the Vitek 2 for identification of seventy-three clinical isolates of enteropathogens.. Journal of thoracic disease. 2014. DOI: 10.3978/j.issn.2072-1439.2014.02.20.
Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.