BACKGROUND

The use of ≥30 mL/Kg fluid bolus in congestive heart failure (CHF) patients presenting with severe sepsis or septic shock remained controversial due to the paucity of data.

METHODS

The retrospective case-control study included 671 adult patients who presented to the emergency department of a tertiary care hospital from January 01, 2017 to December 31, 2019 with severe sepsis or septic shock. Patients were categorized into the CHF group and the non-CHF group. The primary outcome was to evaluate the compliance with ≥30 mL/Kg fluid bolus within 6 hours of presentation. The comparison of baseline characteristics and secondary outcomes were done between the groups who received ≥30 mL/Kg fluid bolus. For the subgroup analysis of the CHF group, it was divided based on if they received ≥30 mL/Kg fluid bolus or not, and comparison was done for baseline characteristics and secondary outcomes. Univariate and multivariable analyses were performed to explore the differences between the groups for in-hospital mortality and mechanical ventilation.

RESULTS

The use of ≥30 mL/Kg fluid bolus was low in both the CHF and non-CHF groups [39% vs. 66% (p<0.05)]. Mortality was higher in the CHF group [33% vs 18% (p<0.05)]. Multivariable analysis revealed that the use of ≥30 mL/Kg fluid bolus decreased the chances of mortality by 12% [OR 0.88, 95% CI 0.82-0.95 (p<0.05)]. The use of ≥30 mL/Kg fluid bolus did not increase the odds of mechanical ventilation [OR 0.99, 95% CI 0.93-1.05 (p = 0.78)]. In subgroup analysis, the use of ≥30 mL/Kg fluid bolus decreased the chances of mortality by 5% [OR 0.95, 95% CI 0.90-0.99, (p<0.05)] and did not increase the odds of mechanical ventilation. The presence of the low ejection fraction did not influence the chance of getting fluid bolus.

CONCLUSION

The use of ≥30 mL/Kg fluid bolus seems to confer protection against in-hospital mortality and is not associated with increased chances of mechanical ventilation in heart failure patients presenting with severe sepsis or septic shock.

Для цитирования: Acharya Roshan, Patel Aakash, Schultz Evan, Bourgeois Michael, Kandinata Natalie, Paswan Rishi, Kafle Smita, Sedhai Yub Raj, Younus Usman. Fluid resuscitation and outcomes in heart failure patients with severe sepsis or septic shock: A retrospective case-control study.. PloS one. 2021. DOI: 10.1371/journal.pone.0256368.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.