DOI 10.1111/pace.13078

Медицинская библиотека · Pacing and clinical electrophysiology : PACE · 2017

Cardiac iodine-123-metaiodobenzylguanidine scintigraphy may be useful to identify pathologic from physiologic sinus bradycardia.

Sunaga Akihiro, Masuda Masaharu, Fujita Masashi, Iida Osamu, Kanda Takashi, Matsuda Yasuhiro, Morozumi Takakazu, Mano Toshiaki, Uematsu Masaaki

Клиническое исследованиеСтатьяПеревод в очереди

Аннотация

BACKGROUND

Sinus bradycardia includes pathologic sick sinus syndrome (SSS) and physiologic bradycardia such as athletes' heart. Pacemaker implantation is indicated for patients with symptomatic SSS; however, the indication remains difficult to determine in those with mild and/or unspecific symptoms. The sympathetic tone is increased in response to reduced cardiac output in SSS, whereas excessive vagal tone has been seen in physiological bradycardia. We sought to determine if cardiac iodine-123-metaiodobenzylguanidine scintigraphy (123 I-MIBG) was useful in differentiating pathologic from physiologic sinus bradycardia.

METHODS

Twenty consecutive patients presenting with continuous sinus bradycardia (heart rate of <50 beats/min) in our outpatient clinic (male, eight patients; age, 70 ± 12 years old) were enrolled. The indication for a pacemaker implantation was determined by an experienced electrophysiologist in compliance with the international guidelines. The sympathetic nervous tone was assessed by cardiac 123 I-MIBG.

RESULTS

Eight patients (40%) were clinically diagnosed as SSS (type I) including four suffering from obvious symptoms (syncope or dizziness) and four suffering from mild symptoms (fatigue), and had an indication for a pacemaker implantation. The patients with SSS indicated for a pacemaker implantation had a lower early heart-to-mediastinum ratio (2.0 ± 0.6 vs 2.5 ± 0.2, P = 0.043), lower delayed heart to mediastinum ratio (2.0 ± 0.8 vs 2.8 ± 0.3, P = 0.026), and higher washout rate (34 ± 6.0 vs 26 ± 6.0, P = 0.008) than those without.

CONCLUSION

Excessive sympathetic tone detected by 123 I-MIBG may serve as an adjunct to determine the indication for a pacemaker implantation in sinus bradycardia.

Для цитирования: Sunaga Akihiro, Masuda Masaharu, Fujita Masashi, Iida Osamu, Kanda Takashi, Matsuda Yasuhiro, Morozumi Takakazu, Mano Toshiaki, Uematsu Masaaki. Cardiac iodine-123-metaiodobenzylguanidine scintigraphy may be useful to identify pathologic from physiologic sinus bradycardia.. Pacing and clinical electrophysiology : PACE. 2017. DOI: 10.1111/pace.13078.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.