MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1097/ico.0000000000001352

Медицинская библиотека · Cornea · 2017

Surface Modifications of the PMMA Optic of a Keratoprosthesis to Improve Biointegration.

Riau Andri K, Venkatraman Subbu S, Dohlman Claes H, Mehta Jodhbir S

СтатьяОбзорПеревод в очереди

Аннотация

Biointegration of a keratoprosthesis (KPro) is critical for the mitigation of various long-term postoperative complications. Biointegration of a KPro occurs between the haptic skirt (corneal graft) and the central optic [poly(methyl methacrylate) (PMMA)]. Various studies have highlighted common problems associated with poor bonding and biointegration between these 2 incompatible biomaterials. Resolution of these issues could be achieved by surface modification of the inert material (PMMA). A calcium phosphate (CaP) coating deposited on dopamine-activated PMMA sheets by simulated body fluid incubation (d-CaP coating) was shown to improve adhesion to collagen type I (main component of corneal stroma) compared with untreated PMMA and PMMA with other surface modifications. However, the d-CaP coating could easily undergo delamination, thereby reducing its potential for modification of KPro optical cylinders. In addition, the coating did not resemble the Ca and P composition of hydroxyapatite (HAp). A novel dip-coating method that involves the creation of cavities to trap and immobilize HAp nanoparticles on the PMMA surface was introduced to address the problems associated with the d-CaP coating. The newly obtained coating offered high hydrophilicity, resistance to delamination, and preservation of the Ca and P composition of HAp. These advantages resulted in improved adhesion strength by more than 1 order of magnitude compared with untreated PMMA. With respect to biointegration, human corneal stromal fibroblasts were able to adhere strongly and proliferate on HAp-coated PMMA. Furthermore, the new coating technique could be extended to immobilization of HAp nanoparticles on 3-mm-diameter PMMA cylinders, bringing it closer to clinical application.

Для цитирования: Riau Andri K, Venkatraman Subbu S, Dohlman Claes H, Mehta Jodhbir S. Surface Modifications of the PMMA Optic of a Keratoprosthesis to Improve Biointegration.. Cornea. 2017. DOI: 10.1097/ico.0000000000001352.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.