MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1590/s0066-782x2011005000056

Медицинская библиотека · Arquivos brasileiros de cardiologia · 2011

Heart failure: comparison between six-minute walk test and cardiopulmonary test.

Carvalho Eduardo Elias Vieira de, Costa Daniela Caetano, Crescêncio Júlio César, Santi Giovani Luiz De, Papa Valéria, Marques Fabiana, Schmidt André, Marin-Neto José Antonio, Simões Marcus Vinícius, Gallo Junior Lourenço

СтатьяПоддержка исследования: вне правительства СШАПеревод в очереди

Аннотация

BACKGROUND

Chronic heart failure (HF) is a syndrome characterized by reduced cardiac output in relation to the metabolic needs of the organism, as well as metabolic and neurohormonal axis abnormalities. Symptoms such as fatigue and dyspnoea are notorious and stress tests are widely used to assess functional capacity, prognosis and effectiveness of therapeutic interventions in this syndrome.

OBJECTIVE

To evaluate the reproducibility of the six-minute walk test (6MW) in patients with HF and correlate the magnitude of the variables reached at peak exercise of the 6MWT with a cardiopulmonary exercise test (CPET).

METHODS

We studied 16 patients (12 men and 4 women) diagnosed with HF FC I-II (NYHA). The volunteers underwent two 6MWT (6MWT'1 and 6MWT'2) with 30-minute interval between them; then, they underwent a maximum CPET.

RESULTS

All variables obtained in the two 6MWT' proved to be significant with high correlations: distance walked (DW) (r = 0.93, p < 0.0001), heart rate (HR) (r = 0.89, p < 0.0001), oxygen consumption (VO2) (r = 0.93, p < 0.0001) and scale of perceived exertion (r = 0.85, p < 0.0001). In turn, all variables analyzed in the 6MWT' showed significant and moderate correlations with the variables obtained from the CPET, namely: peak HR (r = 0.66; p = 0.005); VO2 (r = 0.57; p = 0.02) and VO2 in the CPET and DT in the 6MWT'2 (r = 0.70; p = 0.002).

CONCLUSION

The 6MWT was reproducible in this group of patients with HF (NYHA - I-II) and correlated with the CPET. Therefore, it is a tool for reliable evaluation, and a suitable, safe and low-cost alternative for the prescription of aerobic exercise in patients with HF.

Для цитирования: Carvalho Eduardo Elias Vieira de, Costa Daniela Caetano, Crescêncio Júlio César, Santi Giovani Luiz De, Papa Valéria, Marques Fabiana, Schmidt André, Marin-Neto José Antonio, Simões Marcus Vinícius, Gallo Junior Lourenço. Heart failure: comparison between six-minute walk test and cardiopulmonary test.. Arquivos brasileiros de cardiologia. 2011. DOI: 10.1590/s0066-782x2011005000056.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.