m+Medelevator.RU
← Поиск публикаций
Respiratory medicine · 2024

Salbutamol Easyhaler provides non-inferior relief of methacholine induced bronchoconstriction in comparison to Ventoline Evohaler with spacer: A randomized trial.

СтатьяРандомизированное исследованиеСравнительное исследованиеEquivalence TrialНазвание и аннотация: Перевод в очереди
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Karjalainen Jussi, Vartiainen Ville, Tikkakoski Antti, Malmberg L Pekka, Vuotari Liisa, Lähelmä Satu, Sairanen Ulla, Vahteristo Mikko, Lehtimäki Lauri

Аннотация

BACKGROUND: Salbutamol is a cornerstone for relieving acute asthma symptoms, typically administered through a pressurized metered-dose inhaler (pMDI). Dry powder inhalers (DPIs) offer an alternative, but concerns exist whether DPIs provide an effective relief during an obstructive event.

OBJECTIVE: We aimed to show non-inferiority of Salbutamol Easyhaler DPI compared to pMDI with spacer in treating methacholine-induced bronchoconstriction. Applicability of Budesonide-formoterol Easyhaler DPI as a reliever was also assessed.

METHODS: This was a randomized, parallel-group trial in subjects sent to methacholine challenge (MC) test for asthma diagnostics. Participants with at least 20 % decrease in forced expiratory volume in 1 s (FEV1) were randomized to receive Salbutamol Easyhaler (2 × 200 μg), Ventoline Evohaler with spacer (4 × 100 μg) or Budesonide-formoterol Easyhaler (2 × 160/4.5 μg) as a reliever. The treatment was repeated if FEV1 did not recover to at least -10 % of baseline.

RESULTS: 180 participants (69 % females, mean age 46 yrs [range 18-80], FEV1%pred 89.5 [62-142] %) completed the trial. Salbutamol Easyhaler was non-inferior to pMDI with spacer in acute relief of bronchoconstriction showing a -0.083 (95 % LCL -0.146) L FEV1 difference after the first dose and -0.032 (-0.071) L after the last dose. The differences in FEV1 between Budesonide-formoterol Easyhaler and Salbutamol pMDI with spacer were -0.163 (-0.225) L after the first and -0.092 (-0.131) L after the last dose.

CONCLUSION: The study confirms non-inferiority of Salbutamol Easyhaler to Ventoline Evohaler with spacer in relieving acute bronchoconstriction, making Easyhaler a sustainable and safe reliever for MC test and supports its use during asthma attacks.

Предметные рубрики MeSH

ИП Урсолов Владлен Сергеевич

ИНН 500118482352 · ОГРНИП 314500117700049

Реквизиты и контакты