MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1109/embc.2016.7591301

Медицинская библиотека · Annual International Conference of the IEEE Engineering in Medicine and Biology Society. IEEE Engineering in Medicine and Biology Society. Annual International Conference · 2016

Amplitude based beat detection for atrial fibrillation in pacemaker.

Seung Hwan Lee, Hyoun Seok Myoung, Chang Hoon Kang, Eue Keun Choi, Kyoung Joung Lee

СтатьяПеревод в очереди

Аннотация

Bradycardia is defined as a sinus rhythm of less than 60 beats per minute and atrial tachyarrhythmia including atrial fibrillation (AF) is frequently associated with bradycardia. Pacemaker is the only effective treatment for symptomatic bradycardia and automatic mode switching (AMS) function is built in pacemaker to switch mode in the presence of atrial tachyarrhythmia. AMS algorithms consider appropriate mode switching in case of undersensing or oversensing and this consideration makes their onset time and resynchronization time late. Current pacemakers have onset time from 2.5 seconds to 26 seconds and resynchronization time from 3.4 seconds to 143 seconds according to manufacturers. In this work, we proposed beat detection algorithm based on amplitude difference between peak and trough for accurate extraction of atrial rate achieving faster mode switching. Evaluation of beat detection algorithm was conducted with six canine AF electrogram (EGM) data. Result showed 96.64% sensitivity, 95.5% positive predictive value in average. With this, transition from AF to normal sinus rhythm could be detected faster than existing AMS algorithms. In conclusion, proposed algorithm can efficiently detect beats in EGM during AF and from this, we can implement faster AMS algorithm.

Для цитирования: Seung Hwan Lee, Hyoun Seok Myoung, Chang Hoon Kang, Eue Keun Choi, Kyoung Joung Lee. Amplitude based beat detection for atrial fibrillation in pacemaker.. Annual International Conference of the IEEE Engineering in Medicine and Biology Society. IEEE Engineering in Medicine and Biology Society. Annual International Conference. 2016. DOI: 10.1109/embc.2016.7591301.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.