MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1039/d1an01275d

Медицинская библиотека · The Analyst · 2021

Research on advanced methods of electrochemiluminescence detection combined with optical imaging analysis for the detection of sulfonamides.

Liu Chengxin, Song Dianyou, Yang Zhengchun, Wang Zhiyong, Pan Peng, Liu Jun, Yang Xin, Li Ruirui, Zhu Zikang, Xue Fengjun

СтатьяПеревод в очереди

Аннотация

In this study, a novel method that combines electrochemiluminescence (ECL) analysis and digital image processing was developed for the detection of sulfonamides. This method is based on the ECL system of ruthenium terpyridine, with 1 mM tripropylamine as a co-reactant to enhance the performance. Under the optimal conditions comprising a solution of pH 7 and a scanning rate of 0.08 V s-1, the Pt electrode has an excellent linear detection range from 5 μM to 5 mM, with a detection limit of 0.85 μM (S/N = 3). A wireless camera is used to record the light-emitting process. The recordings are processed, and the digital images are extracted using image-processing algorithms implemented in Python to calculate the brightness value of the image, which has a linear relationship with the logarithm of the sulfonamide concentration. Image analysis simplifies and improves the stability of the ECL analysis process, while also increasing the speed of analysis. The results indicate that the method can successfully detect a sulfonamide concentration of 5 μM. Thus, the analysis method of ECL combined with image processing is feasible for the detection of sulfonamides, thereby displaying its potential applicability as a novel method in drug and food safety, for instance, for sulfonamide detection in antibiotics.

Для цитирования: Liu Chengxin, Song Dianyou, Yang Zhengchun, Wang Zhiyong, Pan Peng, Liu Jun, Yang Xin, Li Ruirui, Zhu Zikang, Xue Fengjun. Research on advanced methods of electrochemiluminescence detection combined with optical imaging analysis for the detection of sulfonamides.. The Analyst. 2021. DOI: 10.1039/d1an01275d.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.