MedElevator Войти в исследования
← Поиск публикаций

DOI 10.3390/medicina58111600

Медицинская библиотека · Medicina (Kaunas, Lithuania) · 2022

Optimizing Concentration of Polyethelene Glycol for Exosome Isolation from Plasma for Downstream Application.

Tangwattanachuleeporn Marut, Muanwien Phijitra, Teethaisong Yothin, Somparn Poorichya

СтатьяПеревод в очереди

Аннотация

BACKGROUND

Exosomes are ubiquitous extracellular nanovesicles secreted from almost all living cells that are thought to be involved in several important cellular processes, including cell-cell communication and signaling. Exosomes serve as a liquid biopsy tool for clinical and translational research. Although many techniques have been used to isolate exosomes, including ultracentrigation, size-exclusion chromatography, and immunocapturing-based techniques, these techniques are not convenient, they require expensive instrumentation, and they are unhandy for clinical samples. Precipitation techniques from available commercial kits that contain polyethelene glycol (PEG) are now widely used, but these kits are expensive, especially if a large number of biological samples are to be processed.

OBJECTIVE

the purpose of this study is to compare and optimize the efficacy of different concentrations of PEG with two commercial kits ExoQuick (SBI) and Total Exosome Isolation (TEI) from Invitrogen in human plasma.

METHODS AND MATERIALS: we determined exosome quantity, size distribution, marker expression, and downstream application.

RESULTS

among the precipitation methods, we found the size of particles and concentrations with 10-20% PEG are similar to ExoQuick and better than TEI. Interestingly, we detected cfDNA with ExoQuick and 10-20% PEG but not TEI and 5% PEG. Moreover, 10% PEG detection of miR-122 and miR-16 expression was superior to ExoQuick and TEI. Furthermore, in proteomics results it also found the identified proteins better than commercial kits but there was a high level of contamination of other proteins in serum.

CONCLUSIONS

together, these findings show that an optimal concentration of 10% PEG serves as a guide for use with clinical samples in exosome isolation for downstream applications.

Для цитирования: Tangwattanachuleeporn Marut, Muanwien Phijitra, Teethaisong Yothin, Somparn Poorichya. Optimizing Concentration of Polyethelene Glycol for Exosome Isolation from Plasma for Downstream Application.. Medicina (Kaunas, Lithuania). 2022. DOI: 10.3390/medicina58111600.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.