Thorax · 2013
Development and validation of a lung transplant-specific disability questionnaire.
СтатьяПоддержка NIH: внешняя программаВалидационное исследованиеНазвание и аннотация: Перевод в очереди
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…
Ошибки и ограничения
История · было → стало
Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.
Singer Jonathan Paul, Blanc Paul David, Dean Y Monica, Hays Steven, Leard Lorriana, Kukreja Jasleen, Golden Jeffrey, Katz Patricia P
Аннотация
BACKGROUND: Lung transplant (LT) aims to extend survival and improve patient-centred outcomes (PCOs) by reducing disability and improving health-related quality of life (HRQL). Few PCO instruments have been validated in LT populations. We aimed to develop and validate a shortened version of the valued life activities (VLA) disability scale specific to LT.
METHODS: We used data from 140 subjects participating in an ongoing cohort study of LT. Subjects completed a survey battery, including VLA items, and physical assessments before LT. To develop a shortened LT-specific VLA (LT-VLA), we iteratively deleted items from a longer 32-item VLA battery, retaining the instrument's conceptual framework, scoring and performance characteristics. We evaluated LT-VLA validity by testing correlations with a HRQL measure (Short Form-12 Physical Function (SF-12 PF) subscale), forced vital capacity % (FVC%) predicted and 6 minute walk distance (6MWD). Responsiveness was evaluated in 84 subjects who completed assessments before and after LT.
RESULTS: The 15-item LT-VLA scoring closely matched the longer VLA (correlations ≥0.96) and had excellent internal consistency (Cronbach's α 0.92). The LT-VLA required only 3 min or less to administer. The LT-VLA, measured as mean difficulty in performing each of the 15 activities queried, correlated with FVC% predicted (r=-0.30), 6MWD (r=-0.38) and SF-12 PF (r=-0.47) (all p<0.01). The LT-VLA mean difficulty was responsive to change from before to after LT (63% improvement; effect size=1.60).
CONCLUSIONS: The LT-VLA is a short, easy to administer, valid and responsive disease-specific PCO instrument that may be useful in clinical and research applications for lung transplantation.
METHODS: We used data from 140 subjects participating in an ongoing cohort study of LT. Subjects completed a survey battery, including VLA items, and physical assessments before LT. To develop a shortened LT-specific VLA (LT-VLA), we iteratively deleted items from a longer 32-item VLA battery, retaining the instrument's conceptual framework, scoring and performance characteristics. We evaluated LT-VLA validity by testing correlations with a HRQL measure (Short Form-12 Physical Function (SF-12 PF) subscale), forced vital capacity % (FVC%) predicted and 6 minute walk distance (6MWD). Responsiveness was evaluated in 84 subjects who completed assessments before and after LT.
RESULTS: The 15-item LT-VLA scoring closely matched the longer VLA (correlations ≥0.96) and had excellent internal consistency (Cronbach's α 0.92). The LT-VLA required only 3 min or less to administer. The LT-VLA, measured as mean difficulty in performing each of the 15 activities queried, correlated with FVC% predicted (r=-0.30), 6MWD (r=-0.38) and SF-12 PF (r=-0.47) (all p<0.01). The LT-VLA mean difficulty was responsive to change from before to after LT (63% improvement; effect size=1.60).
CONCLUSIONS: The LT-VLA is a short, easy to administer, valid and responsive disease-specific PCO instrument that may be useful in clinical and research applications for lung transplantation.