MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1016/j.jchromb.2017.02.015

Медицинская библиотека · Journal of chromatography. B, Analytical technologies in the biomedical and life sciences · 2017

Identification of ace inhibitory cryptides in Tilapia protein hydrolysate by UPLC-MS/MS coupled to database analysis.

Yesmine Ben Henda, Antoine Bonnet, da Silva Ortência Leocádia Nunes Gonzalez, Rogério Boscolo Wilson, Ingrid Arnaudin, Nicolas Bridiau, Thierry Maugard, Jean-Marie Piot, Frédéric Sannier, Stéphanie Bordenave-Juchereau

СтатьяПеревод в очереди

Аннотация

An ultra-performance liquid chromatography-quadrupole-time of flight mass spectrometry method was developed and applied to identify short angiotensin-I-converting enzyme (ACE) inhibitory cryptides in Tilapia (Oreochromis Niloticus) protein hydrolyzate. A database was created with previously identified ACE-inhibitory di- and tripeptides and the lowest molecular weight fraction of Tilapia hydrolysate was analysed for coincidences. Only VW and VY were identified. Further analysis of collected fractions conducted to the identification of 51 different peptides in major fractions. 19 peptides selected were synthesised and tested for their ACE inhibitory potential. TL, TI, IK, LR, LD, IQ, DI, AILE, ALLE, ALIE and AIIE were identified as new ACE inhibitors. The findings from this study point UPLC-MS/MS combined with the creation of a database as an efficient technique to identify specific short peptides within a complex hydrolysate, in addition with de novo sequencing. This efficient characterisation of bioactive factors like cryptides in protein hydrolysates will extend their use as functional foods.

Для цитирования: Yesmine Ben Henda, Antoine Bonnet, da Silva Ortência Leocádia Nunes Gonzalez, Rogério Boscolo Wilson, Ingrid Arnaudin, Nicolas Bridiau, Thierry Maugard, Jean-Marie Piot, Frédéric Sannier, Stéphanie Bordenave-Juchereau. Identification of ace inhibitory cryptides in Tilapia protein hydrolysate by UPLC-MS/MS coupled to database analysis.. Journal of chromatography. B, Analytical technologies in the biomedical and life sciences. 2017. DOI: 10.1016/j.jchromb.2017.02.015.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.