m+Medelevator.RU
← Поиск публикаций
European journal of cardio-thoracic surgery : official journal of the European Association for Cardio-thoracic Surgery · 2017

Concomitant repair for mild aortic insufficiency and continuous-flow left ventricular assist devices.

СтатьяНазвание и аннотация: Перевод в очереди
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Fukuhara Shinichi, Ikegami Hirohisa, Polanco Antonio R, Song Jeremy J, Han Jiho, Takeda Koji, Kurlansky Paul A, Takayama Hiroo, Naka Yoshifumi

Аннотация

OBJECTIVES: Aortic insufficiency (AI) after continuous-flow left ventricular assist device (CF-LVAD) implantation has become a highly relevant subject. However, management of pre-existing mild AI is unknown. We examined the fate of pre-existing mild AI during CF-LVAD support.

METHODS: From March 2004 to October 2015, 446 consecutive patients received CF-LVAD. Of these, 56 (12.6%) patients with pre-existing mild AI were identified. Outcomes were compared between patients who underwent repair [n = 41 (73.2%); Group A] and those who did not [n = 15 (26.8%); Group B].

RESULTS: Group A patients were more likely to have destination therapy intent at device insertion than Group B. Otherwise both groups displayed similar clinical/echocardiographic findings at baseline. There was no difference with respect to the occurrence of postoperative adverse events between groups. Kaplan-Meier analyses revealed the estimated 2-year on-device survival to be 63.3 ± 10.7 and 84.0 ± 10.6% (P = 0.41) and freedom from AI ≥moderate at 2 years to be 81.8 ± 9.7 and 45.0 ± 21.1% (P = 0.031) in Groups A and B, respectively. Furthermore, 83.3% (5 of 6) of Group B patients with large (>1.94 cm/m2; 75th percentile) body surface area-indexed aortic diameter developed ≥moderate AI, while none of the Group B individuals with smaller aortic root (0 of 9) did. In contrast, Group A patients with large indexed aortic root (n = 7) have all been free of AI at 2 years.

CONCLUSIONS: AI progression among CF-LVAD-supported patients with baseline mild AI is highly prevalent. Baseline aortic root diameter may help identify patients with 'borderline' AI lesion needing repair at device insertion.

Предметные рубрики MeSH

ИП Урсолов Владлен Сергеевич

ИНН 500118482352 · ОГРНИП 314500117700049

Реквизиты и контакты