MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1177/0269215513502798

Медицинская библиотека · Clinical rehabilitation · 2013

Assessment of the internal construct validity of the revised High-Level Mobility Assessment Tool for traumatic orthopaedic injuries.

Hill Bridget, Kahn Michelle, Pallant Julie, Williams Gavin

СтатьяВалидационное исследованиеПеревод в очереди

Аннотация

OBJECTIVE

To determine whether the revised High-Level Mobility Assessment Tool (HiMAT) was valid for measuring mobility for people with multi-trauma orthopaedic lower limb injuries.

DESIGN

Cross-sectional study.

SUBJECTS: Participants with lower limb multi-trauma orthopaedic injuries.

METHODS

One complete revised HiMAT was obtained for 106 people within 12 weeks of being allowed to fully weight bear. Rasch analysis was used to assess the overall fit of the model for individuals and items, differential item functioning, local dependency, targeting of items and dimensionality.

RESULTS

The mean revised HiMAT score was 10.5 (SD = 6.8) with a range of 5-30. Rasch analysis of revised HiMAT showed adequate overall fit to the model (P = 0.29) with no misfitting items (fit residual SD = 0.69) or persons (fit residual SD = 0.62). The scale showed good internal consistency (Person Separation Index = 0.91). One item (hopping) demonstrated disordered thresholds, however this item had good fit to the model in all other aspects. The revised HiMAT was unidimensional, and no differential item functioning was detected for gender or age. The revised HiMAT was well targeted for this group with a range of items across all ability levels.

CONCLUSION

The results of this study support the internal construct validity of the revised HiMAT as a well-targeted, unidimensional measure of high-level mobility with no ceiling or floor effect for males and females recovering from multi-trauma orthopaedic lower limb injuries.

Для цитирования: Hill Bridget, Kahn Michelle, Pallant Julie, Williams Gavin. Assessment of the internal construct validity of the revised High-Level Mobility Assessment Tool for traumatic orthopaedic injuries.. Clinical rehabilitation. 2013. DOI: 10.1177/0269215513502798.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.