MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1007/s11356-019-05495-2

Медицинская библиотека · Environmental science and pollution research international · 2019

Potentiometric polyphenol oxidase biosensor for sensitive determination of phenolic micropollutant in environmental samples.

Yashas Shivamurthy Ravindra, Sandeep Shadakshari, Shivakumar Ballagere Puttaraju, Swamy Ningappa Kumara

СтатьяПеревод в очереди

Аннотация

The present study demonstrates the development of polyphenol oxidase (PPO) biosensor for the detection of catechol using strontium copper oxide (SrCuO2) and polypyrrole nanotubes (PPyNT) matrix. The SrCuO2 micro-seeds, a perovskite compound, are synthesized by co-precipitation under pH 8.0. The as-synthesized micro-seeds are characterized by scanning electron microscopy (SEM), field emission scanning electron microscopy (FE-SEM), energy-dispersive X-ray spectroscopy (EDX), and X-ray diffraction spectroscopy (XRD). The proposed sensor is fabricated on pencil graphite (P-Gr) by successive deposition of PPyNT, SrCuO2, and PPO enzyme. The developed PPO/SrCuO2/PPyNT/P-Gr sensor is characterized by cyclic voltammetry (CV), differential pulse voltammetry (DPV), and electrochemical impedance spectroscopy (EIS) techniques. The PPO/SrCuO2/PPyNT/P-Gr displayed excellent electrocatalytic activity towards the oxidation and detection of catechol. The as-developed sensor showed sensitive response ascribing to limit of detection (LOD) of 0.15 μM and sensitivity of 15.60 μA μM-1 cm-2. The fabricated sensor exhibited excellent repeatability and longer shelf life. The proposed biosensor finds its application within the broad linear range of 1-50 μM. Real sample analysis of mineral water, tap water, and domestic wastewater using developed sensor showed acceptable recovery. Hence, the biosensor endeavors its application in environmental monitoring and protection.

Для цитирования: Yashas Shivamurthy Ravindra, Sandeep Shadakshari, Shivakumar Ballagere Puttaraju, Swamy Ningappa Kumara. Potentiometric polyphenol oxidase biosensor for sensitive determination of phenolic micropollutant in environmental samples.. Environmental science and pollution research international. 2019. DOI: 10.1007/s11356-019-05495-2.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.