m+Medelevator.RU
← Поиск публикаций
International journal of cardiology · 2018

Safety and usefulness of acetylcholine provocation test in patients with no culprit lesions on emergency coronary angiography.

СтатьяНазвание и аннотация: Перевод в очереди
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Tateishi Kazuya, Saito Yuichi, Kitahara Hideki, Shoji Toshihiro, Kadohira Tadayuki, Nakayama Takashi, Fujimoto Yoshihide, Kobayashi Yoshio

Аннотация

BACKGROUND: Vasospastic angina (VSA), which often causes acute coronary syndrome (ACS), can be diagnosed by intracoronary acetylcholine (ACh) provocation test. However, the safety and usefulness of ACh provocation test in ACS patients on emergency coronary angiography (CAG) compared to non-emergency settings are unclear.

METHODS: A total of 529 patients undergoing ACh provocation test during emergency or non-emergency CAG were included. Patients with resuscitated cardiac arrest were excluded. The primary endpoint was adverse events defined as a composite of death, ventricular fibrillation or sustained ventricular tachycardia, myocardial infarction, cardiogenic shock, cardiac tamponade, and stroke within 24 h after ACh provocation test.

RESULTS: There were no significant differences of the clinical characteristics between the groups of emergency (n = 84) and non-emergency (n = 445) ACh provocation test. The rate of positive ACh provocation test was similar between the 2 groups (50% vs. 49%, p = 0.81). Similarly, the incidence of adverse events in patients with emergency and non-emergency ACh provocation test did not significantly differ (1.2% vs. 1.3%, p = 1.00).

CONCLUSION: ACh provocation test can be safely performed in ACS patients with no obstructive culprit lesions on emergency CAG, and may be useful to diagnose VSA in those patients.

Предметные рубрики MeSH

ИП Урсолов Владлен Сергеевич

ИНН 500118482352 · ОГРНИП 314500117700049

Реквизиты и контакты