Three-phase CT examination of the pancreatobiliary region using multislice CT with 1-mm collimation.

Itoh Shigeki, Suzuki Koujiro, Iwano Shingo, Satake Hiroko, Ota Toyohiro, Ikeda Mitsuru, Ishigaki Takeo

СтатьяПеревод в очереди

Аннотация

PURPOSE: To evaluate the degree of contrast enhancement and accuracy of imaging of the circulatory phase in the first-pass, second-pass, and third-pass acquisitions in the pancreato-biliary region with 1-mm collimation obtained by multislice computed tomography (CT).

MATERIALS AND

METHODS

In 53 patients, two sequential acquisitions from the porta hepatis to the pancreas were performed during a single breath-hold, followed by a third-pass acquisition including the liver beginning 15 sec after the second-pass acquisition. Contrast enhancement in each acquisition was measured in the aorta, portal vein and its branches, and pancreas. Four experienced radiologists graded using four-point scoring whether or not each acquisition was appropriate for imaging of the arterial phase, pancreatic phase, and portal venous phase.

RESULTS

Aortic enhancement was highest at the beginning of the second-pass acquisition. The portal and splenic veins and pancreas showed maximum enhancement in the second-pass acquisition, while the superior mesenteric vein showed maximum enhancement in the third-pass acquisition. In the visual assessment, significantly higher grades were achieved in the first-pass, second-pass, and third-pass acquisitions with regard to imaging of the arterial phase, pancreatic phase, and portal venous phase, respectively.

CONCLUSION

Multislice CT permits the acquisition of three distinct circulatory phases (arterial, pancreatic, and portal venous phases) in the pancreatobiliary region with 1-mm collimation.

Для цитирования: Itoh Shigeki, Suzuki Koujiro, Iwano Shingo, Satake Hiroko, Ota Toyohiro, Ikeda Mitsuru, Ishigaki Takeo. Three-phase CT examination of the pancreatobiliary region using multislice CT with 1-mm collimation.. Radiation medicine. 2005.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.