MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1111/pace.12934

Медицинская библиотека · Pacing and clinical electrophysiology : PACE · 2016

Acute Sinus Node Dysfunction after Atrial Ablation: Incidence, Risk Factors, and Management.

Killu Ammar M, Fender Erin A, Deshmukh Abhishek J, Munger Thomas M, Araoz Philip, Brady Peter A, Cha Yong-Mei, Packer Douglas L, Friedman Paul A, Asirvatham Samuel J, Noseworthy Peter A, Mulpuru Siva K

СтатьяПеревод в очереди

Аннотация

BACKGROUND

Many patients with atrial fibrillation (AF) or atrial flutter (Aflutter) have concomitant sinus node dysfunction (SND). Ablation may result in injury to the sinus node complex or its blood supply resulting in sinus arrest and need for temporary pacing. We sought to characterize patients who develop acute SND (ASND) during/immediately after AF/Aflutter ablation.

METHODS

We performed a retrospective analysis of AF/Aflutter ablation patients between January 1, 2010 and February 28, 2015 to characterize those who required temporary pacemaker (TPM) implantation due to ASND (sinus arrest, sinus bradycardia <40 beats/min, or junctional rhythm with hemodynamic compromise) following atrial ablation.

RESULTS

Of 2,151 patients, eight patients (<0.5%) with ASND manifesting as sinus arrest (n = 2), severe sinus bradycardia (n = 2), and junctional rhythm with hemodynamic compromise (n = 4) were identified (all male, age 66 ± 9.9 years, 4/8 [50%] persistent AF). AF ablation was performed in four, atypical Aflutter in one, and AF/Aflutter in three patients. The ablation set consisted of: pulmonary vein (PV) isolation (n = 6), roof line ablation (n = 6), mitral annulus-left inferior PV line ablation (n = 5), left atrial appendage-mitral annulus ablation (n = 1), cavotricuspid isthmus ablation (n = 5), and isolation or ablation near the superior vena cava (SVC, n = 4). Patients with peri-SVC ablation were more likely to develop ASND (P = 0.03). All patients received TPM; six received permanent pacemaker before discharge, performed 3.5 days postablation (range 2-6 days). At 3-month device interrogation, all patients were atrially paced >50%.

CONCLUSION

ASND is a rare complication of atrial ablation. It may be more common when peri-SVC ablation is performed and may necessitate permanent pacemaker implantation.

Для цитирования: Killu Ammar M, Fender Erin A, Deshmukh Abhishek J, Munger Thomas M, Araoz Philip, Brady Peter A, Cha Yong-Mei, Packer Douglas L, Friedman Paul A, Asirvatham Samuel J, Noseworthy Peter A, Mulpuru Siva K. Acute Sinus Node Dysfunction after Atrial Ablation: Incidence, Risk Factors, and Management.. Pacing and clinical electrophysiology : PACE. 2016. DOI: 10.1111/pace.12934.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.