m+Medelevator.RU
← Поиск публикаций
JACC. Clinical electrophysiology · 2016

Ablation of Inappropriate Sinus Tachycardia: A Systematic Review of the Literature.

СтатьяСистематический обзорНазвание и аннотация: Перевод в очереди
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Rodríguez-Mañero Moisés, Kreidieh Bahij, Al Rifai Mahmoud, Ibarra-Cortez Sergio, Schurmann Paul, Álvarez Paulino A, Fernández-López Xesús Alberte, García-Seara Javier, Martínez-Sande Luis, González-Juanatey José Ramón, Valderrábano Miguel

Аннотация

OBJECTIVES: The goal of this study was to describe short- and long-term outcomes in all patients referred for inappropriate sinus tachycardia ablation, along with the potential complications of the intervention.

BACKGROUND: Sinus node (SN) ablation/modification has been proposed for patients refractory to pharmacological therapy. However, available data derive from limited series.

METHODS: The electronic databases MEDLINE, Embase, CINAHL, Cochrane, and Scopus were systematically searched (January 1, 1995-December 31, 2015). Studies were screened according to predefined inclusion and exclusion criteria.

RESULTS: A total of 153 patients were included. Their mean age was 35.18 ± 10.02 years, and 139 (90.8%) were female. All patients had failed to respond to maximum tolerated doses of pharmacological therapy (3.5 ± 2.4 drugs). Mean baseline heart rates averaged 101.3 ± 16.4 beats/min according to electrocardiography and 104.5 ± 13.5 beats/min according to 24-h Holter monitoring. Two electrophysiological strategies were used, SN ablation and SN modification, with the latter being used more. Procedural acute success (using variably defined pre-determined endpoints) was 88.9%. Consistently, all groups reported high-output pacing from the ablation catheter to confirm absence of phrenic nerve stimulation before radiofrequency delivery. Need of pericardial access varied between 0% and 76.9%. Thirteen patients (8.5%) experienced severe procedural complications, and 15 patients (9.8%) required implantation of a pacemaker. At a mean follow-up interval of 28.1 ± 12.6 months, 86.4% of patients demonstrated successful outcomes. The symptomatic recurrence rate was 19.6%, and 29.8% of patients continued to receive antiarrhythmic drug therapy after procedural intervention.

CONCLUSIONS: Inappropriate sinus tachycardia ablation/modification achieves acute success in the vast majority of patients. Complications are fairly common and diverse. However, symptomatic relief decreases substantially over longer follow-up periods, with a corresponding high recurrence rate.

Предметные рубрики MeSH

ИП Урсолов Владлен Сергеевич

ИНН 500118482352 · ОГРНИП 314500117700049

Реквизиты и контакты