OBJECTIVES

The goal of this study was to describe short- and long-term outcomes in all patients referred for inappropriate sinus tachycardia ablation, along with the potential complications of the intervention.

BACKGROUND

Sinus node (SN) ablation/modification has been proposed for patients refractory to pharmacological therapy. However, available data derive from limited series.

METHODS

The electronic databases MEDLINE, Embase, CINAHL, Cochrane, and Scopus were systematically searched (January 1, 1995-December 31, 2015). Studies were screened according to predefined inclusion and exclusion criteria.

RESULTS

A total of 153 patients were included. Their mean age was 35.18 ± 10.02 years, and 139 (90.8%) were female. All patients had failed to respond to maximum tolerated doses of pharmacological therapy (3.5 ± 2.4 drugs). Mean baseline heart rates averaged 101.3 ± 16.4 beats/min according to electrocardiography and 104.5 ± 13.5 beats/min according to 24-h Holter monitoring. Two electrophysiological strategies were used, SN ablation and SN modification, with the latter being used more. Procedural acute success (using variably defined pre-determined endpoints) was 88.9%. Consistently, all groups reported high-output pacing from the ablation catheter to confirm absence of phrenic nerve stimulation before radiofrequency delivery. Need of pericardial access varied between 0% and 76.9%. Thirteen patients (8.5%) experienced severe procedural complications, and 15 patients (9.8%) required implantation of a pacemaker. At a mean follow-up interval of 28.1 ± 12.6 months, 86.4% of patients demonstrated successful outcomes. The symptomatic recurrence rate was 19.6%, and 29.8% of patients continued to receive antiarrhythmic drug therapy after procedural intervention.

CONCLUSIONS

Inappropriate sinus tachycardia ablation/modification achieves acute success in the vast majority of patients. Complications are fairly common and diverse. However, symptomatic relief decreases substantially over longer follow-up periods, with a corresponding high recurrence rate.

Для цитирования: Rodríguez-Mañero Moisés, Kreidieh Bahij, Al Rifai Mahmoud, Ibarra-Cortez Sergio, Schurmann Paul, Álvarez Paulino A, Fernández-López Xesús Alberte, García-Seara Javier, Martínez-Sande Luis, González-Juanatey José Ramón, Valderrábano Miguel. Ablation of Inappropriate Sinus Tachycardia: A Systematic Review of the Literature.. JACC. Clinical electrophysiology. 2016. DOI: 10.1016/j.jacep.2016.09.014.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.