MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1016/j.hrthm.2017.02.014

Медицинская библиотека · Heart rhythm · 2017

Reduction in radiation dose for atrial fibrillation ablation over time: A 12-year single-center experience of 2344 patients.

Voskoboinik Aleksandr, Kalman Elana S, Savicky Yonatan, Sparks Paul B, Morton Joseph B, Lee Geoffrey, Kistler Peter M, Kalman Jonathan M

СтатьяПоддержка исследования: вне правительства СШАПеревод в очереди

Аннотация

BACKGROUND

Pulmonary vein isolation (PVI) is a well-established treatment of atrial fibrillation (AF), with contact force (CF)-sensing catheters joining 3-dimensional mapping systems and image integration as technological advancements over the last decade.

OBJECTIVE

The purpose of this study was to analyze trends in radiation exposure for AF ablation over the last 12 years at our center.

METHODS

We reviewed prospectively collected data of 2344 consecutive PVI procedures for either paroxysmal or persistent AF between January 2004 and December 2015. During this period, all cases used 3-dimensional mapping systems, with 8 software and 2 hardware upgrades. Primary endpoints were fluoroscopy time, absorbed dose (Air Kerma in mGy), and effective dose (mSv).

RESULTS

In total, 1914 patients underwent initial PVI, and 430 patients underwent redo PVI using radiofrequency energy. Fluoroscopy time, and absorbed and effective doses significantly and progressively decreased over the 12-year period for initial PVI as follows: 2004-2006: 61 ± 27 minutes; 2007-2009: 46 ± 14 minutes, 1365 ± 1369 mGy, 11.3 ± 12.5 mSv; 2010-2012: 31 ± 11, 464 ± 339 mGy, 9.0 ± 10.4 mSv; and 2013-2015: 17 ± 9 minutes, 304 ± 758 mGy, 5.5 ± 6.7 mSv. CF-sensing catheters were used for 357/508 PVI only cases between 2014 and 2015. Fluoroscopy times (11 ± 5 vs 21 ± 8 minutes; P <.001) and absorbed dose (200 ± 524 vs 470 ± 1326 mGy; P = .004) were significantly shorter with this catheter.

CONCLUSION

Radiation exposure has dramatically decreased over the last decade for PVI and is related to operator experience, annual case volume, technology evolution, and more recently CF-sensing catheters. This has significant implications for both patient and operator long-term risk.

Для цитирования: Voskoboinik Aleksandr, Kalman Elana S, Savicky Yonatan, Sparks Paul B, Morton Joseph B, Lee Geoffrey, Kistler Peter M, Kalman Jonathan M. Reduction in radiation dose for atrial fibrillation ablation over time: A 12-year single-center experience of 2344 patients.. Heart rhythm. 2017. DOI: 10.1016/j.hrthm.2017.02.014.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.