[Determination of nicacid and its metabolites in human plasma by HPLC-MS/MS].
Аннотация
OBJECTIVE
To develop a sensitive HPLC-MS/MS method for the determination of nicacid and its metabolites in human plasma.
METHODS
The assay was conducted with an API 3000 LC-MS/MS system comprising of a Genimi C18 column (50 x 3.00 mm, 3 microm), and an eluate of 0.1% acetic acid-methanol-isopropyl alcohol (98: 1:1), and flow rate was 0.2 mL/min. Acetonitrile was used to precipitate protein from the plasma samples. The loading samples contained the residue from the supernatant that were dissolved in the eluate solution and rinsed by dichloromethane was used as the loading samples. The ion pairs of m/z 124.1-->80.0, m/z 123.1-->80.0, m/z 181.1-->135.0 and m/z 138.1-->92.0 were used to quantify nicacid, niacinamide, nicotinuric acid and 6-methyl nicotinic acid (IS), respectively.
RESULTS
The standard curves of nicacid, niacinamide and nicotinuric were linear in the range of 1.25-320 microg/L, 1.25-1280 microg/L and 1.25-1280 microg/L, respectivly. All with a low determination limits of 1.25 microg/L and a less than 9% within-day and inter-day RSD. The recovery rates reached 89% to 105%.
CONCLUSION
The method is simple, rapid, sensitive, and suitable for the determination of nicacid and its metabolites in human plasma.
Предметные рубрики MeSH
Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Ошибки и ограничения
История · было → стало
Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.
Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.