m+Medelevator.RU
← Поиск публикаций
American journal of health-system pharmacy : AJHP : official journal of the American Society of Health-System Pharmacists · 2022

Use of an argatroban systemic infusion and purge solution in a patient with a percutaneous ventricular assist device with suspected heparin-induced thrombocytopenia.

Клинический случайСтатьяНазвание и аннотация: Перевод в очереди
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Shtoyko Ashley N, Feldman Elizabeth A, Cwikla Gregory M, Darko William, Green G Randall, Seabury Robert W

Аннотация

PURPOSE: Thrombocytopenia can occur when using an Impella percutaneous ventricular assist device (pVAD), and heparin-induced thrombocytopenia (HIT) is often suspected. Data on heparin- and anticoagulant-free purge solutions in these devices are limited. Previous case reports have described argatroban-based purge solutions, both with and without systemic argatroban, at varying concentrations in patients with known or suspected HIT.

SUMMARY: A 33-year-old male was transferred to our institution and emergently initiated on life support with venoarterial extracorporeal membrane oxygenation (ECMO), an Impella pVAD, and continuous venovenous hemofiltration to receive an urgent aortic valve replacement. Over the next several days, the patient's platelet count declined with a nadir of 17 × 103/μL on hospital day 13. The patient's 4T score for probability of HIT was calculated as 4. All heparin products were discontinued on hospital day 15, and the patient was initiated on systemic infusion with argatroban 1,000 μg/mL at a rate of 0.2 μg/kg/min with a purge solution of argatroban 0.05 mg/mL. The systemic infusion remained at a rate of 0.2 μg/kg/min, and the total argatroban dose was, on average, less than 0.25 μg/kg/min. On hospital day 21, the patient was transferred to another institution.

CONCLUSION: Systemic infusion and a purge solution with argatroban were used in a patient with an Impella pVAD with multisystem organ dysfunction and suspected HIT. The patient achieved therapeutic activated partial thromboplastin times without adjustment of the systemic argatroban infusion and did not experience bleeding or thrombosis. Further studies concerning the safety and effectiveness of argatroban-based purge solutions in patients with pVADs are needed.