MedElevator Войти в исследования
← Поиск публикаций

DOI 10.4067/s0034-98872014000900003

Медицинская библиотека · Revista medica de Chile · 2014

[Evaluation of serum insulin levels after an oral glucose load for the diagnosis of insulin resistance].

Arancibia Constanza, Galgani José, Valderas Juan P, Morales Mauricio, Santos José Luis, Pollak Felipe

Аннотация на английскомСтатьяПеревод в очереди

Аннотация

BACKGROUND

In our country, the assessment of insulin resistance (IR) measuring serum insulin levels at 60 and 120 minutes after a 75 g oral glucose tolerance test (OGTT), is usual. However, there is no information about the distribution of serum insulin levels in the Chilean population.

AIM: To assess the distribution of serum insulin levels at 60 and 120 minutes during OGTTs and suggest a statistical cut-off point to estimate the degree of IR.

MATERIAL AND

METHODS

Retrospective analysis of 1815 OGTTs performed in non-diabetic subjects aged between 18 and 75 years, at a university medical center. HOMA-IR (Homeostasis Model Assessment), insulin sensitivity index of Matsuda (ISI-Composite), and their correlation with serum insulin levels at 60 and 120 minutes were calculated.

RESULTS

The 75th percentiles for serum insulin levels at 60 and 120 minutes were 127 and 81 µU/mL, respectively. There was a high correlation between HOMA-IR and ISI-Composite (r = -089, p < 0.001). There was a weaker although significant correlation between HOMA-IR and ISI-Composite and insulin levels at 60 (r = 0.56 and -0.79 respectively, p < 0,001) and 120 minutes (r = 0.54 and -0.75 respectively, p < 0,001).

CONCLUSIONS

We propose 60 and 120 min serum insulin levels of 130 and 80 µU/mL respectively, as cut-off values for normality during OGTT in Chilean normoglycemic individuals.

Для цитирования: Arancibia Constanza, Galgani José, Valderas Juan P, Morales Mauricio, Santos José Luis, Pollak Felipe. [Evaluation of serum insulin levels after an oral glucose load for the diagnosis of insulin resistance].. Revista medica de Chile. 2014. DOI: 10.4067/s0034-98872014000900003.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.