MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1055/s-2007-1015147

Медицинская библиотека · RoFo : Fortschritte auf dem Gebiete der Rontgenstrahlen und der Nuklearmedizin · 1998

[MR-micturating cystourethrography using radical k-space sampling].

Nolte-Ernsting C C, Glowinski A, Katterbach F J, Adam G, Rasche V, Günther R W

СтатьяПеревод в очереди

Аннотация

PURPOSE: To investigate the feasibility of micturating cystourethrography (MCU) by means of real-time MR imaging with radial k-space sampling.

METHODS

The MR-MCU was performed in 7 adult male patients subsequent to a gadolinium(Gd)-DTPA-enhanced excretory MR-urography. The Gd-enhancement of the urethra was visualized by MR-fluoroscopy using a T1-weighted gradient-echo-sequence with radial k-space sampling and a slice thickness of 10 mm.

RESULTS

The proposed technique allowed in all 7 patients a dynamic realtime imaging of the Gd-flow inside the urethra during micturition. The normal anatomy of the entire course of the urethra was demonstrated in each patient, while simultaneously the relation to the prostate and pelvic floor became visible. Furthermore, the urinary bladder could be assessed by interactive repositioning of the slice orientation in any preferred direction. The ureters could also be visualized due to the persisting Gd-enhancement of the upper urinary tract after the preceding MR-urography.

CONCLUSIONS

MR-MCU using Gd-DTPA and radial k-space data acquisition is a novel imaging modality for a real-time visualization of the urethra during micturition without radiation exposure. This method also allows the assessment of the bladder, the pelvic floor, and the Gd-filled upper urinary tract which suggests a potential for the diagnosis of vesicoureteral reflux and urinary incontinence.

Для цитирования: Nolte-Ernsting C C, Glowinski A, Katterbach F J, Adam G, Rasche V, Günther R W. [MR-micturating cystourethrography using radical k-space sampling].. RoFo : Fortschritte auf dem Gebiete der Rontgenstrahlen und der Nuklearmedizin. 1998. DOI: 10.1055/s-2007-1015147.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.