m+Medelevator.RU
← Поиск публикаций
Talanta · 2017

Development of flow systems incorporating membraneless vaporization units and flow-through contactless conductivity detector for determination of dissolved ammonium and sulfide in canal water.

СтатьяНазвание и аннотация: Перевод в очереди
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Alahmad Waleed, Pluangklang Thanakorn, Mantim Thitirat, Cerdà Victor, Wilairat Prapin, Ratanawimarnwong Nuanlaor, Nacapricha Duangjai

Аннотация

Use of membraneless vaporization (MBL-VP) unit with two cone-shaped reservoirs is presented for on-line separation and detection of non-volatile species. A flow system comprising two sets of MBL-VP units with a single in-house capacitively coupled contactless conductivity detector (C4D) was developed for dual determination of ammonium and sulfide ions. Using the continuous-flow section, two zones (280μL) of a sample, either mixed with sodium hydroxide (for ammonium) or hydrochloric acid (for sulfide), are separately delivered into the donor reservoir of the MBL-VP units. The acceptor reservoir contains either 150μL of 15μM HCl solution (for ammonia) or pure water (for hydrogen sulfide), respectively. Vaporization and trapping of the ammonia or hydrogen sulfide gas from the donor reservoir into the liquid acceptor cone occur concurrently in the two separate MBL-VP units. After trapping the gas for 3min, the two 150-μL liquid acceptors are sequentially aspirated through the C4D flow cell for recording the changes in the conductivity. Linear calibrations were obtained for ammonium from 5 to 80µM (Volt = (0.0134 ± 0.0003) [NH4+] - (0.01 ± 0.01), r2 = 0.998) and for sulfide from 5 to 200µM (Volt = (0.0335 ± 0.0009) [S2-] - (0.13 ± 0.09), r2 = 0.996). Analysis time for both analytes is only 320s. Our method was applied to analyze canal water samples. The results agree well with membrane gas-diffusion flow injection techniques, using bromothymol blue for ammonium and methylene blue for sulfide. Recoveries ranged from 95% to 104%.

ИП Урсолов Владлен Сергеевич

ИНН 500118482352 · ОГРНИП 314500117700049

Реквизиты и контакты