Journal of chromatography. B, Analytical technologies in the biomedical and life sciences · 2010

Determination and pharmacokinetics of gastrodin in human plasma by HPLC coupled with photodiode array detector.

Оценочное исследованиеСтатьяНазвание и аннотация: Перевод в очереди
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Ju Xue Hai, Shi Ying, Liu Na, Guo Dong Mei, Cui Xi

Аннотация

In present study, an HPLC method coupled with photodiode array detector (HPLC-PDA) was established for determination and pharmacokinetics of gastrodin (GAS) in human plasma after an oral administration of GAS capsule. In the method, ethanol and dichloromethane were respectively used for deproteinization and purification during the sample preparation procedure. Separation of GAS was achieved on an AichromBond-AQ C18 column (5 microm, 150 mm x 4.6 mm) with the mobile phase of methanol-0.1% phosphoric acid solution (2:98, v/v) at a flow rate of 0.8 ml/min. The wavelength was set at 220 nm and the injection volume was 20 microl. Under the conditions, the calibration curve was linear within the concentration range of 50-4000 ng/ml with the correlation coefficient (r) of 0.99554 (weight=1/X(2)) and the lower limit of quantification (LLOQ) was 50 ng/ml. The inter- and intra-day precisions were less than 11% and the accuracies (%) were within the range of 95.55-103.78%. The extraction recoveries were over 65% with RSDs less than 5.50%. The GAS was proved to be stable under tested conditions. Thus, the method was valid enough to be applied for pharmacokinetic study of GAS in human plasma. The pharmacokinetic parameters of GAS in human plasma after an oral administration of 200 mg GAS capsule were described as: C(max), 1484.55+/-285.05 ng/ml; T(max), 0.81+/-0.16 h; t(1/2alpha), 3.78+/-2.33 h; t(1/2beta), 6.06+/-3.20 h; t(1/2Ka), 0.18+/-0.53 h; K(12), 0.18+/-0.41/h; K(21), 0.20+/-0.16/h; K(10), 4.11+/-15.81/h; V1/F, 180.35+/-89.44 L; CL/F, 62.50+/-140.03 l/h; AUC(0-->t), 5619.41+/-1972.88 (ng/ml) h; and AUC(0-->infinity), 7210.26+/-3472.74 (ng/ml) h, respectively. These will be useful for the clinical application of GAS.

Предметные рубрики MeSH

ИП Урсолов Владлен Сергеевич

ИНН 500118482352 · ОГРНИП 314500117700049

Реквизиты и контакты