Медицинская библиотека · Acta psychiatrica Scandinavica · 2000

Comparison of the standard and the computerized versions of the Symptom Check List (SCL-90-R): a randomized trial.

Schmitz N, Hartkamp N, Brinschwitz C, Michalek S, Tress W

Клиническое исследованиеСравнительное исследованиеСтатьяРандомизированное исследованиеПеревод в очереди

Аннотация

OBJECTIVE

The purpose of this study was to examine whether computer administration of the Symptom Check List (SCL-90-R) is equivalent to paper-and-pencil originals.

METHOD: 282 psychosomatic outpatients were randomly assigned to computer or paper-and-pencil conditions. Statistical equivalence tests were used to examine psychometric equivalence for the means. Reliabilities and correlations were compared for the two methods of administration.

RESULTS

No systematic differences were observed in group means for most of the subscales. Subjects of the computer-administered group scored higher on the SCL-90-R subscale 'Obsessive-Compulsive' and 'Anger-Hostility' than the control subjects. Gender and administration mode interaction was observed for one subscale, while age and administration interaction was observed for another subscale.

CONCLUSION

Using computer-administered tests makes administration and scoring of tests more efficient. The differences between the two administration modes were small, although noticeable. Further research is needed to determine whether computer environment, computer experience and age may influence the test results.

Для цитирования: Schmitz N, Hartkamp N, Brinschwitz C, Michalek S, Tress W. Comparison of the standard and the computerized versions of the Symptom Check List (SCL-90-R): a randomized trial.. Acta psychiatrica Scandinavica. 2000. DOI: 10.1034/j.1600-0447.2000.102002147.x.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.