MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1002/bmc.1362

Медицинская библиотека · Biomedical chromatography : BMC · 2010

Determination of chlorpheniramine in human plasma by HPLC-ESI-MS/MS: application to a dexchlorpheniramine comparative bioavailability study.

Moreno Ronilson Agnaldo, Oliveira-Silva Diogo, Sverdloff Carlos Eduardo, Borges Bruno Carter, Rebelo Galvinas Paulo Alexandre, Astigarraga Rafael Barrientos, Borges Ney Carter

Оценочное исследованиеСтатьяПеревод в очереди

Аннотация

In the present study a fast, sensitive and robust validated method to quantify chlorpheniramine in human plasma using brompheniramine as internal standard (IS) is described. The analyte and the IS were extracted from plasma by LLE (diethyl ether-dichloromethane, 80:20, v/v) and analyzed by HPLC-ESI-MS/MS. Chromatographic separation was performed using a gradient of methanol from 35 to 90% with 2.5 mm NH(4)OH on a Gemini Phenomenex C(8) 5 microm column (50 x 4.6 mm i.d.) in 5.0 min/run. The method fitted to a linear calibration curve (0.05-10 ng/mL, R > 0.9991). The precision (%CV) and accuracy ranged, respectively: intra-batch from 1.5 to 6.8% and 99.1 to 106.6%, and inter-batch from 2.4 to 9.0%, and 99.9 to 103.1%. The validated bioanalytical procedure was used to assess the comparative bioavailability in healthy volunteers of two dexchlorpheniramine 2.0 mg tablet formulations (test dexchlorpheniramine, Eurofarma, and reference Celestamine, Schering-Plough). The study was conducted using an open, randomized, two-period crossover design with a 2 week washout interval. Since the 90% confidence interval for C(max) and AUC ratios were all within the 80-125% interval proposed by ANVISA and FDA, it was concluded that test and reference formulations are bioequivalent concerning the rate and the extent of absorption.

Для цитирования: Moreno Ronilson Agnaldo, Oliveira-Silva Diogo, Sverdloff Carlos Eduardo, Borges Bruno Carter, Rebelo Galvinas Paulo Alexandre, Astigarraga Rafael Barrientos, Borges Ney Carter. Determination of chlorpheniramine in human plasma by HPLC-ESI-MS/MS: application to a dexchlorpheniramine comparative bioavailability study.. Biomedical chromatography : BMC. 2010. DOI: 10.1002/bmc.1362.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.