m+Medelevator.RU
← Поиск публикаций
Journal of glaucoma · 2018

Needling With 5-Fluorouracil (5-FU) After XEN Gel Stent Implantation: 6-Month Outcomes.

СтатьяНазвание и аннотация: Перевод в очереди
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Arnljots Thorsteinn S, Kasina Rafael, Bykov Vladimir J N, Economou Mario A

Аннотация

PURPOSE: The purpose of this study was to evaluate frequency, safety, and efficacy of needling in patients that underwent XEN Gel Stent implantation.

METHODS: Retrospective case review of 19 eyes of 57 consecutive patients (61 eyes) with primary open-angle glaucoma or pseudoexfoliative glaucoma that previously underwent implantation of XEN45 alone or in combination with cataract surgery followed by needling procedure with 5-FU. Success was defined at 2 IOP levels: ≤21 mm Hg and ≤15 mm Hg, with or without additional glaucoma medications. Treatment failure was defined as IOP>21 mm Hg or <5 mm Hg, need for additional glaucoma surgery or loss of light perception.

RESULTS: Totally 19 of 61 eyes that underwent XEN gel implantation had subsequent needling and were included. Preneedling IOP was 26.2±9.5 and postneedling IOP at last follow-up 15.4±3.7 mm Hg (P=0.0001). Overall success rates of 17 (90%) and 13 eyes (69%) were observed at the ≤21 mm Hg and ≤15 mm Hg level, respectively. Preneedling and postneedling visual acuity and number of medications remained unchanged (P>0.05). Two eyes (10%) were categorized as treatment failures. No major complications occurred. Mean follow-up was 203.8±142.2 (range, 22 to 456) days.

CONCLUSIONS: Needling revision following XEN gel stent implantation showed a good IOP-lowering effect without significant increase in number of antiglaucoma medications, decrease in visual acuity, nor any major complications. Further studies with long-term follow-up and a larger number of patients are needed to fully assess the safety and efficacy of this procedure.