Improved visualisation of real-time recordings during third generation cryoballoon ablation: a comparison between the novel short-tip and the second generation device.

Клиническое исследованиеСравнительное исследованиеСтатьяНазвание и аннотация: Перевод в очереди
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Mugnai Giacomo, de Asmundis Carlo, Hünük Burak, Ströker Erwin, Moran Darragh, Hacioglu Ebru, Ruggiero Diego, Poelaert Jan, Verborgh Christian, Umbrain Vincent, Beckers Stefan, Coutino-Moreno Hugo Enrique, Takarada Ken, de Regibus Valentina, Brugada Pedro, Chierchia Gian-Battista

Аннотация

BACKGROUND: The third-generation Cryoballoon Advance Short-tip (CB-ST) has been designed with a 40 % shortened tip length compared with the former second generation CB advance device (CB-A). Ideally, a shorter tip should permit an improved visualisation of real-time recordings in the pulmonary vein (PV) due to a more proximal positioning of the inner lumen mapping catheter. We sought to compare the incidence of visualisation of real-time recordings in patients having undergone ablation with the CB-ST with patients having received CB-A ablation.

METHODS: All patients having undergone CB ablation using CB-ST technology and the last 500 consecutive patients having undergone CB-A ablation were analysed. Exclusion criteria were the presence of an intracavitary thrombus, uncontrolled heart failure, moderate or severe valvular disease, and contraindications to general anaesthesia.

RESULTS: A total of 600 consecutive patients (58.1 ± 12.9 years, 64 % males) were evaluated (100 CB-ST and 500 CB-A ablations). Real-time recordings were significantly more prevalent in the CB-ST population compared with CB-A group (85.7 vs 67.2 %, p < 0.0001). Real-time recordings could be more frequently visualised in the CB-ST group in all types of veins (LSPV 89 vs 73.4 %, p = 0.0005; LIPV 84 vs 65.6 %, p = 0.0002; RSPV 87 vs 67.4 %, p < 0.0001; RIPV 83 vs 62.4 %, p < 0.0001).

CONCLUSION: The rate of visualisation of real-time recordings is significantly higher during third-generation CB-ST ablation if compared to the second-generation CB-A device. Real-time recordings can be visualised in approximately 85.7 % of veins with this novel cryoballoon.